ابحث في المحطة بأكملها

a hyperbaric oxygen chamber

Compare soft- and hard-shell MACY-PAN chambers for one to four users, seated, lying, walk-in, wheelchair, and stretcher-access layouts. Shanghai Baobang Medical Equipment Co., Ltd. manufactures complete systems with the chamber, air compression, oxygen supply, controls, and model-specific cooling equipment.

Start with your intended use and target pressure. We will narrow the chamber type and identify the site and configuration details needed for an itemized quote.

What You Are Buying: Chamber, Pressure, and Oxygen System

A complete hyperbaric oxygen chamber system creates a controlled, above-atmospheric-pressure environment and supplies oxygen through the configuration specified for that model. MACY-PAN systems coordinate the chamber body, air compressor, oxygen concentrator, pressure controls, valves, and cooling equipment. The exact package varies by chamber family.

The chamber pressure and the breathing-gas specification are separate purchasing parameters. A higher ATA rating does not by itself establish the device's intended use, oxygen concentration, regulatory status, or suitability for a particular user. Ask the supplier to state whether each pressure figure is a normal working pressure, an adjustable range, or a maximum value.

Soft-shell or hard-shell?

TypeTypical MACY-PAN configurationsPressure range represented in this product familySelection implications
Soft-shellPortable lying, portable sitting, wheelchair-access, and multi-user fabric chambers1.3–1.5 ATA, depending on modelLower chamber weight and foldable or movable formats make room changes and storage easier. Confirm the complete system footprint, entry method, zipper clearance, and intended-use documentation for the destination market.
Hard-shell monoplaceLying, sitting, transparent, and walk-in chambers for one user1.5–2.0 ATA, depending on modelA rigid pressure boundary supports higher-pressure configurations and fixed installations. Compare internal diameter, door opening, user position, system weight, and service clearance.
Hard-shell multiplaceSeated, bench, bed-platform, and configurable layoutsUp to 2.0 ATA in the represented HE5000 familyCapacity and walk-in access can support commercial or institutional workflows. Verify rated occupancy, internal layout, operator position, utilities, room access, and local installation requirements.
Tell Us Your Intended Use

Choose by Intended Use, Pressure, Capacity, and Site

Choose the device category only after defining how and where the chamber will be used. A home wellness installation, a commercial recovery business, and a regulated medical service can require different equipment documentation, supervision, room controls, and operating procedures even when the requested pressure is the same.

Five decisions that narrow the model range

  1. Define the intended use and destination market. State whether the project is for home use, a wellness or sports facility, a veterinary application, or a regulated clinical service. For U.S. medical use, request the exact model's FDA 510(k) information and intended use; a company registration, quality-system certificate, or another model's record does not establish clearance for the unit being purchased.
  2. Specify the pressure correctly. Record the requested pressure in ATA and ask whether it is absolute pressure. At standard sea-level conditions, 1.5 ATA is approximately 7.35 psig above ambient pressure, while 2.0 ATA is approximately 14.70 psig above ambient pressure. Site altitude changes the relationship between absolute and gauge pressure.
  3. Set occupancy and user position. Decide how many users must enter at once and whether they will lie down, sit, recline, walk in, enter by wheelchair, or transfer on a stretcher. Rated occupancy and usable internal layout matter more than the number of seats visible in a photograph.
  4. Measure the delivery and installation path. Provide door, hallway, elevator, stair, and turning dimensions as well as the final room size. Hard-shell units also require verified floor loading, equipment clearance, ventilation, electrical supply, and access for maintenance.
  5. Define the complete system and operating plan. Confirm the chamber, compressor, oxygen source, cooling, controls, communication equipment, masks or breathing interfaces, training, documentation, spare parts, and acceptance testing included in the offer.

Quick selection guide

Your primary constraintStart withConfirm before ordering
Foldable format or easier relocationPortable soft-shell lying or sitting chamberChamber and accessory weights, packed size, setup area, entry clearance, pressure options
One user who prefers to lie downST701/ST801/ST901 soft-shell or HP-series hard-shellInternal length and diameter, access method, pressure, total system package
One user who prefers to sit or walk inL1/ST1700/ST2200, HP750, or HE5000 MonoHeadroom, legroom, seat adjustment, door opening, exterior dimensions
Wheelchair accessMC4000 N/U familyClear entry dimensions, turning space, floor layout, rated occupancy
Stretcher transferMC750Stretcher dimensions and load, transfer path, door operation, communication and pressure-control arrangement
Two to four seated usersHE5000 Fort, HE5000, or HE5000 PlusRated occupancy, chosen interior, pressure, room access, system weight, utilities
Get a Model Recommendation

Build a Quote You Can Compare

Hyperbaric chamber prices change with the pressure rating, shell structure, internal size, occupancy, access system, oxygen and air equipment, cooling, controls, interior configuration, electrical version, documentation, and delivery scope. A chamber-only figure cannot be compared directly with a complete installed-system quote.

Ask every supplier to use the same quote boundary. The equipment schedule should identify the chamber, compressor, oxygen concentrator or oxygen-supply interface, cooling equipment, controls, communication system, breathing interfaces, furniture, filters, initial consumables, spare parts, manuals, and test records. The commercial schedule should identify export packing, freight, insurance, import charges, inside delivery, installation, commissioning, training, acceptance, and warranty responsibility.

Quote comparison checklist

Quote itemInformation to require
Product identityLegal manufacturer, brand, complete model and submodel, quantity, new/used status
Technical configurationWorking pressure and reference basis, occupancy, dimensions, weight, voltage, air/oxygen flow, included accessories
DocumentationIntended-use statement, manuals, installation requirements, model-specific regulatory and quality documents requested for the destination market
التوصيلIncoterm, destination, packing, freight, insurance, duties/taxes responsibility, inside-delivery scope
Site servicesInstallation, commissioning, training, acceptance tests, travel, tools, and work by local contractors
Lifecycle supportWarranty start point and coverage, maintenance intervals, common spares, consumables, remote/onsite support
Request an Itemized Quote

Plan the Room, Utilities, Safety, and Acceptance

A fixed chamber project begins with a measured installation path and room plan. Record the narrowest door and hallway, elevator capacity, turning radius, floor loading, final equipment position, service clearances, and the route for moving the chamber and auxiliary equipment into place. The chamber's exterior dimensions alone do not describe the full installed footprint.

Confirm the selected model's electrical supply, ventilation, ambient limits, air and oxygen arrangement, cooling connections, exhaust routing, communication system, and maintenance access. Local authorities and qualified professionals should define applicable building, electrical, fire, pressure-vessel, medical-device, and operating requirements for the intended use and jurisdiction.

Before occupied use, match the delivered model, serial number, system components, labels, manuals, and ordered configuration to the contract. Commissioning should follow the model-specific manufacturer procedure and record pressure control, relief, ventilation, gas supply, alarms, communication, emergency functions, and any required leakage or functional checks.

Information to send for a site review

  • Destination country, city, and intended use
  • Room plan and clear photos of the final location
  • Door, corridor, elevator, stair, and turning dimensions
  • Floor construction and verified load capacity for hard-shell units
  • Available voltage, frequency, outlet or disconnect arrangement, and grounding
  • Ventilation, cooling, air/oxygen supply, exhaust, and fire-safety provisions
  • Requested delivery boundary: curbside, inside delivery, installation, commissioning, or training
Submit Your Site Details

Work Directly with the MACY-PAN Manufacturer

Shanghai Baobang Medical Equipment Co., Ltd. develops and manufactures MACY-PAN soft- and hard-shell hyperbaric chambers in Shanghai, China. Its range covers portable lying and sitting chambers, hard-shell monoplace systems, walk-in multiplace cabins, wheelchair-access layouts, stretcher systems, and veterinary chambers.

The 2026 product catalog records 19 years of hyperbaric chamber industry experience and supply to more than 123 countries and regions. An in-house research and design team supports product development, while OEM and ODM services support distributors and private-label programs.

Available customization depends on the model. Options represented in the product materials include color, logo, interface language, control-panel configuration on selected HP models, and interior features on the HE5000 family. Final drawings and the itemized quotation should identify every approved option before production.

Discuss OEM or Project Requirements

Hyperbaric Chamber Buying FAQ

What does ATA mean on a hyperbaric chamber?

ATA means atmospheres absolute, measured from absolute vacuum. At standard sea-level conditions, 1.0 ATA is ambient atmospheric pressure, so a chamber at 2.0 ATA has approximately 1 atmosphere, or 14.70 psi, of gauge pressure above ambient. Ask suppliers to label psi as psia or psig so comparisons use the same reference.

How do I choose between a monoplace and multiplace chamber?

Choose monoplace when one user per session fits the operating model and a smaller cabin meets access needs. Choose multiplace when the project requires simultaneous users, an attendant position, a configurable seated or bed layout, or higher throughput. Compare rated occupancy, usable internal space, operator requirements, cleaning turnover, and the installation footprint.

Does ‘portable’ mean one person can move the complete system?

No. Portable describes the chamber's deployment format, not the lifting weight of every component. Check the separate weights and packed dimensions of the chamber, compressor, oxygen concentrator, cooler, and accessories, then plan storage and movement for the complete system.

Ask a Technical Question

Request a Hyperbaric Chamber Quote

Submit the form for a model recommendation, any necessary configuration questions, and an itemized quotation.

  • الهاتف: 0086-180-1702-3916
  • البريد الإلكتروني: rachel@macypan.com
  • واتساب: 0086-180-1702-3916
  • العنوان: المبنى 15، رقم 899 طريق غينان، منطقة سونغجيانغ، شنغهاي، الصين 201617

Describe the intended use, target pressure, number of users, access method, installation space, voltage, destination, and any OEM or documentation requirements.

مستودع الشركة التابعة للولايات المتحدة الأمريكية الدعم الفني المحلي بالولايات المتحدة الأمريكية
*
*

بلدك

*
تقديم!
تم التقديم بنجاح!
فشل التقديم
عنوان بريد إلكتروني غير صحيح!
رقم هاتف غير صحيح!

اعثر على غرفة Hbot المناسبة لك

مستودع الشركة التابعة للولايات المتحدة الأمريكية الدعم الفني المحلي بالولايات المتحدة الأمريكية

أخبرنا بما تحتاج إليه. وسنقدم لك توصيات بشأن الطرازات المناسبة والأسعار وخيارات التسليم.

*
*

الشحن إلى:

الولايات المتحدة الأمريكيةكنداأخرى
تقديم!
تم التقديم بنجاح!
فشل التقديم
عنوان البريد الإلكتروني غير صالح!
رقم هاتف غير صحيح!

سيُغلق هذا في 0 ثوانٍ