a hyperbaric oxygen chamber
Compare soft- and hard-shell MACY-PAN chambers for one to four users, seated, lying, walk-in, wheelchair, and stretcher-access layouts. Shanghai Baobang Medical Equipment Co., Ltd. manufactures complete systems with the chamber, air compression, oxygen supply, controls, and model-specific cooling equipment.
Start with your intended use and target pressure. We will narrow the chamber type and identify the site and configuration details needed for an itemized quote.
The HE5000 combines a walk-in hard-shell cabin, external controls, and a configurable interior for multi-user installations.
What You Are Buying: Chamber, Pressure, and Oxygen System
A complete hyperbaric oxygen chamber system creates a controlled, above-atmospheric-pressure environment and supplies oxygen through the configuration specified for that model. MACY-PAN systems coordinate the chamber body, air compressor, oxygen concentrator, pressure controls, valves, and cooling equipment. The exact package varies by chamber family.
The chamber pressure and the breathing-gas specification are separate purchasing parameters. A higher ATA rating does not by itself establish the device's intended use, oxygen concentration, regulatory status, or suitability for a particular user. Ask the supplier to state whether each pressure figure is a normal working pressure, an adjustable range, or a maximum value.
Soft-shell or hard-shell?
| Type | Typical MACY-PAN configurations | Pressure range represented in this product family | Selection implications |
|---|---|---|---|
| Soft-shell | Portable lying, portable sitting, wheelchair-access, and multi-user fabric chambers | 1.3–1.5 ATA, depending on model | Lower chamber weight and foldable or movable formats make room changes and storage easier. Confirm the complete system footprint, entry method, zipper clearance, and intended-use documentation for the destination market. |
| Hard-shell monoplace | Lying, sitting, transparent, and walk-in chambers for one user | 1.5–2.0 ATA, depending on model | A rigid pressure boundary supports higher-pressure configurations and fixed installations. Compare internal diameter, door opening, user position, system weight, and service clearance. |
| Hard-shell multiplace | Seated, bench, bed-platform, and configurable layouts | Up to 2.0 ATA in the represented HE5000 family | Capacity and walk-in access can support commercial or institutional workflows. Verify rated occupancy, internal layout, operator position, utilities, room access, and local installation requirements. |
Choose by Intended Use, Pressure, Capacity, and Site
Choose the device category only after defining how and where the chamber will be used. A home wellness installation, a commercial recovery business, and a regulated medical service can require different equipment documentation, supervision, room controls, and operating procedures even when the requested pressure is the same.
Five decisions that narrow the model range
- Define the intended use and destination market. State whether the project is for home use, a wellness or sports facility, a veterinary application, or a regulated clinical service. For U.S. medical use, request the exact model's FDA 510(k) information and intended use; a company registration, quality-system certificate, or another model's record does not establish clearance for the unit being purchased.
- Specify the pressure correctly. Record the requested pressure in ATA and ask whether it is absolute pressure. At standard sea-level conditions, 1.5 ATA is approximately 7.35 psig above ambient pressure, while 2.0 ATA is approximately 14.70 psig above ambient pressure. Site altitude changes the relationship between absolute and gauge pressure.
- Set occupancy and user position. Decide how many users must enter at once and whether they will lie down, sit, recline, walk in, enter by wheelchair, or transfer on a stretcher. Rated occupancy and usable internal layout matter more than the number of seats visible in a photograph.
- Measure the delivery and installation path. Provide door, hallway, elevator, stair, and turning dimensions as well as the final room size. Hard-shell units also require verified floor loading, equipment clearance, ventilation, electrical supply, and access for maintenance.
- Define the complete system and operating plan. Confirm the chamber, compressor, oxygen source, cooling, controls, communication equipment, masks or breathing interfaces, training, documentation, spare parts, and acceptance testing included in the offer.
Quick selection guide
| Your primary constraint | Start with | Confirm before ordering |
|---|---|---|
| Foldable format or easier relocation | Portable soft-shell lying or sitting chamber | Chamber and accessory weights, packed size, setup area, entry clearance, pressure options |
| One user who prefers to lie down | ST701/ST801/ST901 soft-shell or HP-series hard-shell | Internal length and diameter, access method, pressure, total system package |
| One user who prefers to sit or walk in | L1/ST1700/ST2200, HP750, or HE5000 Mono | Headroom, legroom, seat adjustment, door opening, exterior dimensions |
| Wheelchair access | MC4000 N/U family | Clear entry dimensions, turning space, floor layout, rated occupancy |
| Stretcher transfer | MC750 | Stretcher dimensions and load, transfer path, door operation, communication and pressure-control arrangement |
| Two to four seated users | HE5000 Fort, HE5000, or HE5000 Plus | Rated occupancy, chosen interior, pressure, room access, system weight, utilities |
Explore Six Hyperbaric Chamber Options

The blue ST701 uses a horizontal soft-shell format with a compact support base and a clear top viewing panel.
MACY-PAN ST701 Portable Lying Hyperbaric Oxygen Chamber
The ST701 is a flexible, single-user lying chamber for buyers who prioritize a compact portable format. Its system pairs the TPU chamber with pressure control, air compression, and oxygen-generation equipment.
- Pressure options1.3 ATA or 1.5 ATA, depending on configuration
- Chamber materialTPU composite fabric
- Oxygen concentrator output93% ± 3%
- Rated system power600 W
- Supply voltage110 V or 220 V configuration
- Published operating noiseBelow 50 dB

The HE5000 Fort presents a compact multiplace cabin with a side entry door, external display, and multiple pressure fittings.
MACY-PAN HE5000 Fort Multiplace Hyperbaric Oxygen Chamber
The HE5000 Fort is a hard-shell multiplace chamber with face-to-face seating. Its walk-in layout serves projects that need seated capacity in a rigid cabin without moving to the larger HE5000 Plus footprint.
- Pressure specification2.0 ATA
- Chamber materialMedical-grade stainless steel
- Exterior size89 × 46 × 74 in. (2,270 × 1,167 × 1,874 mm)
- Chamber weight1,146 lb (520 kg)
- LayoutFace-to-face multiplace seating
- CoolingHigh-efficiency air-cooling system

The white HE5000 shows the walk-in door, cabin lighting, external display, and a seated interior arrangement.
MACY-PAN HE5000 Three-Person Hyperbaric Oxygen Chamber
This HE5000 entry focuses on the three-person interior shown on its linked product page. It uses the same HE5000 base model and exterior envelope as the later 2.0 ATA entry, while presenting shared seated capacity as the primary selection point.
- Pressure specification2.0 ATA
- Chamber materialMedical-grade stainless steel
- Exterior size82 × 64 × 69 in. (2,070 × 1,616 × 1,749 mm)
- Chamber weight1,433 lb (650 kg)
- Interior optionsTwo seats, three seats, bed platform, or bench
- Oxygen supplyOxygen concentrator
- Air supplyAir compressor
- CoolingHigh-efficiency air-cooling system

The range image shows a rigid horizontal chamber with a transparent end door, side connections, and a freestanding controller.
MACY-PAN Soft- and Hard-Shell Hyperbaric Chamber Range
This range-level option supports buyers who want to compare flexible and rigid chamber structures before selecting a specific model. MACY-PAN offers portable lying and sitting formats as well as hard-shell monoplace and multiplace configurations.
- Soft-shell pressure range1.3–1.5 ATA in this family
- Hard-shell pressure range1.5–2.0 ATA in this family
- Represented materialsTPU, stainless steel, and aluminum, depending on model
- Range-listing oxygen summary93% ± 3% oxygen concentrator output
- Range-listing electrical summary110 V or 220 V, 50/60 Hz; confirm the exact version in the model quotation
- Available formatsLying, sitting, walk-in, wheelchair-access, stretcher, and multiplace

The MC750 image shows the stretcher aligned with the open cylindrical chamber for a horizontal transfer.
MACY-PAN MC750 Stretcher Hyperbaric Oxygen Chamber
The MC750 is a single-user hard-shell chamber with a sliding stretcher for users who cannot enter through a conventional seated or lying transfer. Inside/outside pressure-release controls and a communication system support coordination between the occupant and operator.
- Pressure specification1.8 ATA
- Chamber materialStainless steel
- Chamber size87 in. long × 30 in. diameter (220 × 75 cm)
- Chamber weight291 lb (132 kg)
- Integrated-unit air flow80 L/min
- Oxygen flow option5 or 10 L/min
- Supply voltage110, 220, or 240 VAC, ±10%

The dark gray HE5000 provides a full-height entry, exterior monitoring screen, and a wide rigid cabin for a fixed site.
MACY-PAN HE5000 2.0 ATA Hard-Shell Hyperbaric Oxygen Chamber
This separate HE5000 entry focuses on the adjustable-pressure and system-flow configuration stated on its linked product page. It shares the HE5000 base model and exterior envelope with the earlier three-person entry; buyers should compare the confirmed interior and equipment schedule rather than treat the two entries as different chamber models.
- Adjustable operating range1.1–2.0 ATA
- Maximum specified working pressure2.0 ATA
- Chamber material304 stainless steel with a polycarbonate viewing window
- Exterior size82 × 64 × 69 in. (2,070 × 1,616 × 1,749 mm)
- Chamber weightApproximately 1,433 lb (650 kg)
- Configured system flow140 L/min air plus 20 L/min oxygen
- Supply options110/220 VAC, 50/60 Hz
Build a Quote You Can Compare
Hyperbaric chamber prices change with the pressure rating, shell structure, internal size, occupancy, access system, oxygen and air equipment, cooling, controls, interior configuration, electrical version, documentation, and delivery scope. A chamber-only figure cannot be compared directly with a complete installed-system quote.
Ask every supplier to use the same quote boundary. The equipment schedule should identify the chamber, compressor, oxygen concentrator or oxygen-supply interface, cooling equipment, controls, communication system, breathing interfaces, furniture, filters, initial consumables, spare parts, manuals, and test records. The commercial schedule should identify export packing, freight, insurance, import charges, inside delivery, installation, commissioning, training, acceptance, and warranty responsibility.
Quote comparison checklist
| Quote item | Information to require |
|---|---|
| Product identity | Legal manufacturer, brand, complete model and submodel, quantity, new/used status |
| Technical configuration | Working pressure and reference basis, occupancy, dimensions, weight, voltage, air/oxygen flow, included accessories |
| Documentation | Intended-use statement, manuals, installation requirements, model-specific regulatory and quality documents requested for the destination market |
| Delivery | Incoterm, destination, packing, freight, insurance, duties/taxes responsibility, inside-delivery scope |
| Site services | Installation, commissioning, training, acceptance tests, travel, tools, and work by local contractors |
| Lifecycle support | Warranty start point and coverage, maintenance intervals, common spares, consumables, remote/onsite support |
Plan the Room, Utilities, Safety, and Acceptance
A fixed chamber project begins with a measured installation path and room plan. Record the narrowest door and hallway, elevator capacity, turning radius, floor loading, final equipment position, service clearances, and the route for moving the chamber and auxiliary equipment into place. The chamber's exterior dimensions alone do not describe the full installed footprint.
Confirm the selected model's electrical supply, ventilation, ambient limits, air and oxygen arrangement, cooling connections, exhaust routing, communication system, and maintenance access. Local authorities and qualified professionals should define applicable building, electrical, fire, pressure-vessel, medical-device, and operating requirements for the intended use and jurisdiction.
Before occupied use, match the delivered model, serial number, system components, labels, manuals, and ordered configuration to the contract. Commissioning should follow the model-specific manufacturer procedure and record pressure control, relief, ventilation, gas supply, alarms, communication, emergency functions, and any required leakage or functional checks.
Information to send for a site review
- Destination country, city, and intended use
- Room plan and clear photos of the final location
- Door, corridor, elevator, stair, and turning dimensions
- Floor construction and verified load capacity for hard-shell units
- Available voltage, frequency, outlet or disconnect arrangement, and grounding
- Ventilation, cooling, air/oxygen supply, exhaust, and fire-safety provisions
- Requested delivery boundary: curbside, inside delivery, installation, commissioning, or training
Work Directly with the MACY-PAN Manufacturer
Shanghai Baobang Medical Equipment Co., Ltd. develops and manufactures MACY-PAN soft- and hard-shell hyperbaric chambers in Shanghai, China. Its range covers portable lying and sitting chambers, hard-shell monoplace systems, walk-in multiplace cabins, wheelchair-access layouts, stretcher systems, and veterinary chambers.
The 2026 product catalog records 19 years of hyperbaric chamber industry experience and supply to more than 123 countries and regions. An in-house research and design team supports product development, while OEM and ODM services support distributors and private-label programs.
Available customization depends on the model. Options represented in the product materials include color, logo, interface language, control-panel configuration on selected HP models, and interior features on the HE5000 family. Final drawings and the itemized quotation should identify every approved option before production.
Discuss OEM or Project RequirementsHyperbaric Chamber Buying FAQ
What does ATA mean on a hyperbaric chamber?
ATA means atmospheres absolute, measured from absolute vacuum. At standard sea-level conditions, 1.0 ATA is ambient atmospheric pressure, so a chamber at 2.0 ATA has approximately 1 atmosphere, or 14.70 psi, of gauge pressure above ambient. Ask suppliers to label psi as psia or psig so comparisons use the same reference.
How do I choose between a monoplace and multiplace chamber?
Choose monoplace when one user per session fits the operating model and a smaller cabin meets access needs. Choose multiplace when the project requires simultaneous users, an attendant position, a configurable seated or bed layout, or higher throughput. Compare rated occupancy, usable internal space, operator requirements, cleaning turnover, and the installation footprint.
Does ‘portable’ mean one person can move the complete system?
No. Portable describes the chamber's deployment format, not the lifting weight of every component. Check the separate weights and packed dimensions of the chamber, compressor, oxygen concentrator, cooler, and accessories, then plan storage and movement for the complete system.
Request a Hyperbaric Chamber Quote
Submit the form for a model recommendation, any necessary configuration questions, and an itemized quotation.
- Phone: 0086-180-1702-3916
- Email: rachel@macypan.com
- WhatsApp: 0086-180-1702-3916
- Address: Bldg.15, No.899 Guinan Rd, Songjiang Dist, Shanghai, China 201617
HBOTSALE