전체 방송국 검색

2.0 ata hyperbaric chamber

A 2.0 ATA chamber is a complete pressure-vessel project, not a pressure number alone. Compare horizontal monoplace, walk-in monoplace, and multiperson MACY-PAN configurations, then match the chamber, air system, oxygen delivery, room, electrical supply, operating plan, and target-market documentation.

What 2.0 ATA Means for Your Project

2.0 ATA means an absolute pressure of about 202.7 kPa or 29.4 psia. At sea level, that is approximately 101.3 kPa or 14.7 psi above ambient pressure. A quote should state whether 2.0 ATA is the normal working pressure, the maximum setting, or another limit; these values are not interchangeable.

Pressure is one selection input. The intended use, chamber construction, rated occupancy, pressurizing gas, breathing-gas arrangement, control system, site conditions, operator responsibilities, and target-market requirements determine whether a configuration fits a project. A higher pressure does not by itself establish better performance, regulatory clearance, or suitability for a particular medical use.

Before comparing prices, ask each supplier to define the same system boundary. A complete comparison should include the chamber, compressor, oxygen source or oxygen interface, cooling and ventilation equipment, controls, safety devices, accessories, installation, training, shipping scope, warranty, and required documentation.

Choose the Chamber Format Before the Finish Options

Start with posture, entry method, rated occupancy and site constraints. Finish and interior options come after the functional format is selected.

Horizontal monoplace

A horizontal monoplace chamber supports one user in a lying position. Compare the internal diameter, entry height, patient-transfer method, observation window, external supervision, and the full equipment footprint. HP2202 is the MACY-PAN horizontal 2.0 ATA family, with several diameter options listed in the product dossier.

Walk-in monoplace

A walk-in monoplace chamber gives one user an upright seating arrangement and a door-style entry. Confirm the clear opening, threshold, interior seat layout, external dimensions, floor load, and emergency-exit procedure. HE5000 Mono is the single-user walk-in format in the current product family.

Multiperson

A multiperson chamber can increase capacity, but the rated occupancy must be confirmed for the exact model and layout. Room access, seating, internal communication, breathing interfaces, supervision, evacuation planning, cleaning turnover, and ventilation become part of the operating design. HE5000 Fort, HE5000, and HE5000 Plus cover different footprints and occupancy needs.

Available 2.0 ATA Options

These six entries preserve the exact links and image pairs supplied for this page. Confirm the final model, variant, configuration and market documents in the written quotation.

Silver MACY-PAN HE5000 Fort chamber with door-style entry and touch display

HE5000 Fort 2.0 ATA Chamber

A compact multiperson-family configuration with a door-style entry and customizable interior options.

  • 작동 압력2.0 ATA
  • External size2,270 × 1,167 × 1,874 mm / 89 × 46 × 74 in
  • Weight520 kg / 1,146 lb
  • OptionsColor, logo, electric seating, ceiling and ambient lighting
White MACY-PAN HE5000 three-person hyperbaric chamber with front door

HE5000 3-Person Chamber

A larger seated multiperson configuration. Freeze occupancy, seat layout, oxygen interfaces, and operating requirements in the technical specification before order.

  • 작동 압력2.0 ATA
  • External size2,070 × 1,616 × 1,749 mm / 82 × 64 × 69 in
  • Weight650 kg / 1,433 lb
  • Nominal noise limit45 dB
Bronze hard-shell hyperbaric chamber supplied through the MACY-PAN OEM program

MACY-PAN Manufacturer and OEM Program

Shanghai Baobang Medical Equipment Co., Ltd. develops soft- and hard-shell MACY-PAN chambers for single-user and multiperson projects.

  • Product scopeSoft- and hard-shell chamber families
  • Service scopeOEM and ODM
  • CustomizationColor, logo, language, control-panel and interior options by model

Site and System Requirements to Confirm Before a Quote

The chamber should be quoted as part of an installed system. Provide the supplier with the intended use, country of installation, number of users, preferred posture, target working pressure, expected daily cycles, room plan, access route, power supply, ventilation, floor information, oxygen source, staffing model, and requested delivery scope.

CheckInformation to confirm
Model identityManufacturer, brand, complete model and variant
압력Normal working pressure, maximum allowable working pressure and relief settings
OccupancyRated users, staff position, seats or bed layout and emergency egress
Chamber envelopeExternal and internal dimensions, door opening, weight and service clearances
UtilitiesVoltage, frequency, grounding, compressor, oxygen source, cooling and ventilation
Installation routeCrate dimensions, door widths, turning space, lifting plan and floor capacity
OperationTrained operator, supervision, communication, cleaning and daily inspection
DeliveryIncoterm, packing, commissioning, acceptance test, training and warranty response

MACY-PAN systems can be configured for 110 V or 220 V and 50 or 60 Hz where the selected model supports it. The final electrical and system configuration must be stated in the approved quotation and drawings rather than inferred from a family-level page.

Safety and Document Review

A 2.0 ATA chamber contains people inside a pressure boundary, so procurement should start with traceable model-level engineering, test and regulatory documents.

Engineering file

Request the pressure-vessel design basis, applicable standard and edition, drawings, material records, pressure and leak test records, relief-device information, control and alarm logic, labeling, installation instructions, operation manual, maintenance plan, and acceptance criteria for the exact model and manufacturing site.

Target-market status

For the United States, hyperbaric chambers are Class II medical devices under product code CBF. Verify the exact manufacturer, device name, 510(k) record, intended use, model coverage, labeling, and current status. Establishment registration, device listing, ISO 13485 certification, CE documentation, or an ASME certificate does not by itself prove that every quoted model is cleared for every intended use.

Installed operation

Confirm the pressurizing gas, breathing-gas delivery, fire-prevention controls, electrical grounding, prohibited materials, patient screening, operator training, communication, emergency decompression, cleaning, preventive maintenance, and local inspection requirements before service begins.

Customization and Project Delivery

Shanghai Baobang Medical Equipment Co., Ltd. provides OEM and ODM support for MACY-PAN chamber projects. Available options vary by model. Documented examples include color and logo choices, control-panel customization for HP2202, and electric seating, ceiling effects, or ambient lighting for the HE5000 family.

1. Define the use and site

Share the installation country, buyer role, intended use, chamber format, occupancy, room and utility information, target schedule, and required market documents.

2. Freeze the technical configuration

Approve the model, pressure values, dimensions, materials, system components, breathing interfaces, controls, safety devices, finish options, drawings, packing and acceptance criteria.

3. Confirm delivery responsibility

The order should assign responsibility for export documents, import, transport, lifting, installation, commissioning, operator training, acceptance testing, warranty support and spare parts.

4. Accept against the approved file

Match the delivered model and serial number to the contract, drawings, labels, test records, manuals and certificates. Record installation and functional checks before routine operation.

자주 묻는 질문

Is 2.0 ATA the same as 2 bar or 2 bar gauge?

No. ATA is absolute pressure. At sea level, 2.0 ATA is about 2.03 bar absolute and about 1.01 bar gauge. Require the quotation and instrument labels to identify absolute or gauge pressure.

Does 2.0 ATA automatically make a chamber a clinical HBOT system?

No. Pressure alone is insufficient. Clinical use also depends on hard-shell construction, breathing gas, the exact device's intended use and regulatory status, site standards, professional supervision, and operating procedures.

Which MACY-PAN 2.0 ATA format should I request?

Choose by posture, entry method, rated occupancy, room access, floor load, supervision and workflow. HP2202 is a horizontal monoplace family; HE5000 Mono is a walk-in single-user format; HE5000 Fort, HE5000 and HE5000 Plus serve larger multiperson projects.

What information is needed for an accurate quotation?

Provide the installation country, intended use, users per session, preferred posture, exact room and route dimensions, utilities, expected daily cycles, oxygen arrangement, required documents, customization, shipping destination, installation scope and training needs.

Can the chamber be customized?

Yes, within the selected model's engineering limits. MACY-PAN offers OEM and ODM services. Confirm every requested option in the approved drawing, configuration list and quotation.

Request a 2.0 ATA Chamber Proposal

  • Phone: 0086-180-1702-3916
  • Email: rachel@macypan.com
  • WhatsApp: 0086-180-1702-3916
  • Address: Bldg.15, 889 Guinan Rd, Songjiang Dist, Shanghai, China 201617

Tell us the installation country, intended use, users per session, room dimensions, electrical supply, target schedule and required documentation. We will match the chamber and system scope to the project.

미국 지사 창고 미국 현지 기술 지원
*
*

귀하의 국가

*
제출 중!
제출 성공!
제출하지 못했습니다!
이메일 주소가 잘못되었습니다!
전화번호가 잘못되었습니다!

나에게 딱 맞는 Hbot 챔버 찾기

미국 지사 창고 미국 현지 기술 지원

원하시는 사항을 알려주세요. 적합한 모델과 가격, 배송 옵션을 안내해 드리겠습니다.

*
*

배송지:

미국캐나다기타
제출 중!
제출 성공!
제출하지 못했습니다!
이메일 주소가 잘못되었습니다!
전화번호가 잘못되었습니다!

다음에서 닫힙니다. 0 초