Buscar en toda la estación

at home hyperbaric chamber for sale

Choose a Home Chamber by Pressure, Space, and Capacity

Compare portable TPU systems and hard-shell sitting chambers for one to three users. MACY-PAN supplies complete chamber systems from Shanghai Baobang Medical Equipment Co., Ltd., with pressure options from 1.3 to 2.0 ATA and configurations for lying, sitting, or shared use.

Tell us the intended use, number of users, preferred position, room dimensions, destination ZIP code, and required pressure. We will match those details to a model and define the chamber, air compression, oxygen generation, cooling, controls, shipping, and support included in the quote.

Choose the Chamber Around the User, Room, and Intended Use

A home hyperbaric chamber should match a defined use case before pressure or price is compared. Start with who will enter the chamber, whether the person must sit or lie down, whether an attendant or second user needs space, and who will monitor each session from outside.

Select the structure

  • Portable TPU chamber: A flexible chamber can reduce chamber-body weight and may be folded for storage. The complete system still includes compression, oxygen, cooling, controls, hoses, and safety accessories, so its total storage and operating footprint must be measured.
  • Hard-shell chamber: A rigid sitting or walk-in design provides a fixed interior layout and supports higher-pressure configurations in this product range. Its weight, doorway clearance, turning path, floor loading, and installation space require confirmation before ordering.

Match the position and capacity

  • Choose a lying chamber when the user needs a full-length resting position and can transfer through the specified entrance.
  • Choose a sitting chamber when an upright or reclined seat better fits the user and room.
  • Choose a multi-person chamber only after confirming rated occupancy, seat layout, oxygen connections, supervision, and an emergency exit plan.

Define pressure in the same terms

Compare working pressure in ATA absolute, not an unlabeled psi or “atmospheres” figure. The listed options span 1.3 to 2.0 ATA, but a higher maximum pressure does not determine suitability by itself. Intended use, chamber structure, breathing-gas arrangement, operating instructions, supervision, and U.S. regulatory status must support the same configuration.

For a U.S. purchase, ask for the legal manufacturer, complete model and sub-model, intended use, labeling, instructions for use, and the applicable FDA record. “Home,” “personal,” and “for sale” describe the sales context; they do not establish prescription status, clearance, or permission for unsupervised operation.

Send My Selection Requirements

Confirm the Room Before You Confirm the Model

Measure the complete delivery and operating path. Record the narrowest door, hallway, stair, elevator, and turning clearance from the unloading point to the final room. For a rigid chamber, obtain the packed and installed dimensions and weight before confirming that the floor and route can accept it.

The operating room must hold the chamber and every external component while preserving access to controls, air inlets, exhaust, electrical connections, emergency controls, and maintenance panels. Add the manufacturer’s required clearance instead of using the chamber dimensions as the total room footprint.

Home site checklist

  • Floor and access: Confirm floor loading, level placement, doorway clearance, elevator capacity, and a clear emergency path.
  • Power: Match voltage, frequency, circuit capacity, plug, grounding, and any backup-power requirement to the exact system. The listed products include 110/220 V configurations, but the final electrical schedule belongs in the written order.
  • Air and temperature: Maintain the ventilation, temperature, humidity, and dust limits stated for the model. Allow heat from the compressor, oxygen equipment, and cooling system to leave the room.
  • Fire safety: Plan the room around the fire-protection, electrical, grounding, clearance, and emergency-access requirements for the exact chamber and oxygen arrangement.
  • Monitoring and communication: Provide an outside operating position with a clear view of the user, audible alarms, communication, and immediate access to emergency controls.
  • Service space: Leave room for inspection, cleaning, filter changes, hose replacement, and removal of external equipment without blocking the exit route.

Send room photographs and a dimensioned route sketch with the inquiry. A rigid multi-person chamber may require a different delivery method from a flexible single-person system even when both fit inside the final room.

Check My Room and Delivery Route

Home Hyperbaric Chambers Available from MACY-PAN

Blue flexible horizontal chamber on a white and light-gray background, clearly labeled MACY-PAN 701 hyperbaric O₂ chamber; no people.

Blue flexible horizontal chamber on a white and light-gray background, clearly labeled “MACY-PAN 701 hyperbaric O₂ chamber”; no people.

HB-HOME-S1500 Home Hyperbaric Chamber

This flexible TPU home system offers selectable 1.3 or 1.5 ATA pressure and a full-length interior for lying use. Inside and outside touch controls operate the pressure and timing functions, while the listed cooling and drying equipment supports room-based operation. The supplied image is labeled “MACY-PAN 701 hyperbaric O₂ chamber,” while this card uses the HB-HOME-S1500 name stated on the designated product page. Confirm the image, complete model, and specifications together in the written quote.

  • Presión nominal1.3 ATA or 1.5 ATA
  • Concentración de oxígeno93% ± 3% from the listed PSA system
  • Internal chamber length2,250 mm / 88.6 in
  • Published chamber diameter range80–90 cm / 31.5–35.4 in
  • Chamber materialHigh-strength TPU composite
  • Flujo de aireAt least 85 L/min
  • ControlsTouch screens inside and outside the chamber
  • Safety configurationThree independent pressure-relief paths
White and light-gray rigid chamber on a white background, with a large transparent window and door on the left showing a warm orange interior and bench, plus a blue display at the upper right; no people.

White and light-gray rigid chamber on a white background, with a large transparent window and door on the left showing a warm orange interior and bench, plus a blue display at the upper right; no people.

HE5000 Hyperbaric Chamber for 2–3 People

This rigid multi-person HE5000 configuration provides a large shared interior for two to three people. The designated product page lists adjustable pressure up to 2.0 ATA, a 160 cm chamber diameter, climate control, internal seating, communication, and 110/220 V power options.

  • Presión máxima de servicio2.0 ATA, adjustable
  • Capacidad nominal2–3 people
  • Chamber dimensions160 cm diameter × 220 cm length / 63.0 × 86.6 in
  • Published oxygen concentration93% ± 3%
  • Flujo de aire120 L/min
  • Power supply110/220 V, 50/60 Hz
  • Published total power2,500 W
  • InteriorSeating, LED lighting, intercom, and air conditioning
Front-right view of a white and light-gray HE5000 Fort chamber with a single central transparent door, a blue touchscreen on the right, and HE5000 Fort branding on the body; white background with no people.

Front-right view of a white and light-gray HE5000 Fort chamber with a single central transparent door, a blue touchscreen on the right, and HE5000 Fort branding on the body; white background with no people.

HE5000 Fort 1–2 Person Sitting Hyperbaric Chamber

The HE5000 Fort is a rigid sitting chamber for one or two users. Its product package lists the chamber cabin, oxygen generation, enhanced air compression, and air conditioning, with touchscreen controls and internal and external pressure-relief operation.

  • Maximum pressure2.0 ATA, adjustable
  • Capacidad1-2 personas
  • External size89 × 46 × 74 in / 2,261 × 1,168 × 1,880 mm
  • Published oxygen concentration90%+
  • Included on the product pageChamber cabin, two 10 L oxygen concentrators, enhanced air compressor, and air conditioner
  • ControlsTouchscreen system with pressure and session information
  • Safety functions listedDoor-close sensing, manual and automatic pressure relief, emergency relief, power-outage alarm, and internal/external pressure displays
Front-right view of a white and light-gray rigid sitting chamber with a central transparent door, a blue touchscreen on the right, and MACY-PAN HE5000 Fort hyperbaric O₂ chamber printed on the body; white background with no people.

Front-right view of a white and light-gray rigid sitting chamber with a central transparent door, a blue touchscreen on the right, and “MACY-PAN HE5000 Fort hyperbaric O₂ chamber” printed on the body; white background with no people.

High-Efficiency Home Hyperbaric Chamber System

This product listing covers two different builds: a horizontal hard-shell chamber and a seated soft-shell chamber for one or two users. The hard-shell build requires a verified delivery route and floor loading; the soft-shell build still needs space for compression, oxygen, cooling, controls, and hoses. The written quote must name one complete sub-model and its corresponding specifications.

  • Structure choicesHorizontal hard shell or seated soft shell
  • Listed working-pressure range across the page1.5–2.0 ATA; confirm the selected sub-model's rated pressure
  • Listed capacity across the page1–2 people; confirm the selected sub-model's rated occupancy
  • Oxygen generationPSA molecular-sieve system
  • Power110/220 V
  • Published lead time for standard configurations7–15 business days

Compare the Four Listed Options

OptionStructure and positionPresiónCapacidadKey sizePublished web price*Best initial fit
HB-HOME-S1500Flexible TPU, lying1.3 or 1.5 ATANot stated on the designated product page; confirm in the written quote88.6 in internal length; 31.5–35.4 in published diameter$14,865A full-length flexible chamber where storage and chamber-body weight matter
HE5000 for 2–3 peopleRigid shared chamberUp to 2.0 ATA2–363.0 in diameter × 86.6 in length$64,100A large room with a planned shared-use layout and a verified delivery route
Fuerte HE5000Rigid sittingUp to 2.0 ATA1–289 × 46 × 74 in external sizeRequest current priceOne or two seated users who need a defined cabin and equipment package
High-Efficiency SystemHorizontal hard shell or seated soft shell; exact build to be selected1.5–2.0 ATA across the listing1–2 across the listingExact dimensions must be assigned to the selected sub-model$13,560A buyer who wants to configure the structure before the exact sub-model is quoted

*Published web prices were checked on October 9, 2026. They are reference listing prices, not installed prices or guaranteed current offers. The written quote must identify the exact model, equipment package, destination, shipping, taxes, installation, and validity period.

Use the table to shortlist equipment; establish operating settings from the selected device instructions and qualified professional direction.

Ask MACY-PAN to Compare My Shortlist

Compare Price Only After the Configuration Matches

A chamber-only price cannot be compared directly with a complete-system or installed price. Ask each quote to separate the chamber, compressor, oxygen concentrator or supply interface, cooling and drying equipment, controls, communication equipment, furniture, hoses, safety accessories, starter consumables, and spare parts.

Costs that can change the delivered total

  • Pressure rating, chamber structure, diameter, occupancy, seat or bed layout, and entrance design
  • Oxygen generation, airflow, cooling, dehumidification, controls, communication, and optional interior equipment
  • Crating, freight, insurance, customs entry, duty, tax, residential delivery, indoor handling, and rigging
  • Site preparation, electrical work, ventilation, installation, commissioning, acceptance testing, and training
  • Filters, cleaning supplies, preventive maintenance, inspections, replacement parts, remote support, and on-site service

Request the equipment price, delivered price, and installed price as separate totals. The quote should also identify its currency, issue date, expiration date, payment stages, shipping term, delivery location, and the party responsible for import and local compliance.

Request an Itemized Delivered Quote

Put the Complete Buying Package in Writing

Shanghai Baobang Medical Equipment Co., Ltd. manufactures soft and hard MACY-PAN chambers for single- and multi-person configurations.

OEM and ODM options include color, branding, language, and selected controls or interior features. Lock each approved option to the complete model, signed drawing, and revision-controlled configuration list before production.

Send with your inquiry

  • Intended use and U.S. destination
  • Number of users, sitting or lying preference, mobility and transfer needs, and outside monitoring plan
  • Requested working pressure and the professional or regulatory basis for that request
  • Room dimensions, access-route measurements, floor information, voltage, frequency, ventilation, and photographs
  • Required delivery date, indoor placement needs, installation expectations, and training language

Lock into the offer and order

  • Legal manufacturer, brand, complete model and sub-model, equipment status, country of origin, and serial-number process
  • Rated working pressure, maximum permitted pressure, relief settings, capacity, dimensions, weight, materials, power, airflow, and oxygen-system details
  • Approved drawings, configuration revision, labeling, instructions, installation requirements, maintenance schedule, safety information, test records, and applicable U.S. regulatory documentation
  • Acceptance criteria for identity, documentation, pressure, relief, ventilation, oxygen or gas supply, controls, alarms, communication, and emergency functions
  • Warranty start date, term, covered parts, labor, travel, return shipping, exclusions, response method, spare-parts availability, and support after discontinuation

At delivery, match the nameplate, model, serial number, packing list, manuals, approved configuration, and test records before commissioning.

During commissioning, test each agreed acceptance item with the procedure and pass criteria for that model. Record the result, personnel, date, instrument where applicable, and resolution of any failed item before loaded operation.

Build My Purchase Specification

Home Hyperbaric Chamber FAQ

Can I operate a home hyperbaric chamber alone from inside?

Do not assume that internal controls permit unattended operation. The exact instructions and local requirements determine operator training and supervision. Plan for an outside person who can observe the user, maintain communication, recognize alarms, and operate emergency controls throughout the session.

Can I connect my own oxygen concentrator or other oxygen source?

Only use the oxygen equipment and connection method documented for the exact chamber system. Changing the source, flow, tubing, interface, or control arrangement can change oxygen concentration, ventilation, alarms, and fire risk.

What should be removed before a session?

Follow the model-specific instructions for clothing, electronics, personal-care products, cleaning residues, and other chamber items. Keep ignition sources and unapproved electrical or static-producing materials out of the operating area, and confirm that every material is compatible with the chamber and oxygen arrangement.

How should the chamber be cleaned and maintained?

Use the cleaning agents, intervals, filters, inspections, and replacement parts specified for the model. Stop operation and contact the manufacturer or a qualified service provider if there is structural damage, leakage, an alarm, an unusual odor or sound, or a control fault.

Ask a Product Question

Request a Configuration-Based Quote

Tell us which listed model you are considering and how it will be used. Include the number of users, sitting or lying preference, requested pressure, room dimensions, access route, destination ZIP code, available power, and the delivery, installation, training, and support you expect. MACY-PAN will reply with a model recommendation and an itemized scope for confirmation.

  • Phone: 0086-180-1702-3916
  • Email: rachel@macypan.com
  • WhatsApp: 0086-180-1702-3916
  • Address: Bldg.15, No.899 Guinan Rd, Songjiang Dist, Shanghai, China 201617

Include the model, intended use, number of users, position, target pressure, room and doorway dimensions, voltage, ZIP code, and requested delivery date.

Almacén de la filial estadounidense Asistencia técnica local en EE.UU.
*
*

Su país

*
¡Presentación!
Envío correcto.
¡Sumisión fallida!
Dirección de correo electrónico incorrecta
¡Número de teléfono incorrecto!

Encuentra la cámara Hbot más adecuada para ti

Almacén de la filial estadounidense Asistencia técnica local en EE.UU.

Dinos qué necesitas. Te recomendaremos los modelos más adecuados, los precios y las opciones de entrega.

*
*

Envío a:

EE.UU.CanadáOtros
¡Presentación!
Envío correcto.
¡Sumisión fallida!
Dirección de correo electrónico no válida
¡Número de teléfono incorrecto!

Esto se cerrará en 0 segundos