buy hyperbaric oxygen therapy chamber
Compare soft and hard MACY-PAN chamber options from 1.3 to 2.0 ATA, including single-person and multi-person formats, then request a model-matched proposal.
A MACY-PAN hard-shell hyperbaric chamber configured for a professional indoor setting.
Start With Intended Use, Market, and Operating Conditions
Define the intended use before choosing a pressure or chamber style. A chamber for a U.S. medical setting, a supervised institutional program, a residential environment, or product distribution may require different device documentation, operating controls, personnel, and site approvals.
For a U.S. medical-device purchase, match the quoted manufacturer and complete model to its intended use and applicable FDA record. Establishment registration or device listing is not the same as 510(k) clearance, and a record for one model does not automatically cover every chamber sold under the same brand.
Set these requirements before comparing products:
- Intended use and target market
- Single-person or multi-person capacity
- Lying, seated, reclined, or walk-in access
- Required working pressure and whether the stated value is absolute pressure
- Air and oxygen delivery configuration
- Operator, supervision, and emergency-response plan
- Delivery route, room conditions, electrical service, ventilation, grounding, and fire-safety requirements
- Budget for the complete installed system and ongoing operation
Compare Chamber Formats Before You Compare Prices
Ask the supplier to identify normal working pressure, maximum permitted pressure, relief settings, and whether each value is stated as ATA absolute pressure, psia, or psig. A higher number does not establish that a chamber fits its intended use or target market.
| Format | Typical MACY-PAN range represented in the product catalog | Selection focus |
|---|---|---|
| Portable lying soft chamber | Single-user and wider lying formats; 1.3, 1.4, or 1.5 ATA options on listed soft models | Folded storage, complete-system portability, entry height, internal width, and supervision |
| Seated or reclining soft chamber | Compact single-user and extended seated/reclining formats; 1.3, 1.4, or 1.5 ATA options on listed models | Posture, floor space, entry opening, compressor/oxygen equipment, and room ventilation |
| Lying hard-shell chamber | HP1501 at 1.5 or 1.6 ATA; HP2202 and HP2202 DIA at 2.0 ATA | Diameter, transfer height, pressure specification, integrated equipment, cooling, and delivery path |
| Upright or walk-in hard-shell chamber | Single-person seated or walk-in formats, including 2.0 ATA models | Door and threshold dimensions, user access, emergency egress, floor loading, and operator visibility |
| Multi-person chamber | Soft two-person and hard-shell multi-seat layouts | Rated occupancy, internal layout, staff plan, communication, evacuation, utilities, and cleaning turnover |
Screen labels such as “portable,” “home,” “large,” and “multi-person” by external dimensions, internal space, entrance size, system weight, rated occupancy, and installation requirements.
Ask for a Format RecommendationMACY-PAN Chamber Options to Review

The MACY-PAN HP2202-75 hard-shell chamber shown in a horizontal, single-user configuration.
MACY-PAN HP2202-75 Lying-Type Hard-Shell Chamber
The HP2202-75 is a 2.0 ATA lying-type hard-shell chamber for buyers who need a rigid single-user format with an integrated control system. The linked 75 cm version is part of the HP2202 series, which uses a medical-grade stainless-steel chamber body and a 220 cm (87 in) length.
- Working pressure2.0 ATA
- Chamber formatLying-type hard shell
- Chamber bodyMedical-grade stainless steel
- Linked version75 cm (30 in) diameter
- Series length220 cm (87 in)
- System arrangementIntegrated unit with air conditioning
- Custom options listed for the seriesColor, logo, and control panel

A rigid MACY-PAN chamber with a wide transparent viewing section and integrated exterior controls.
HSHMC-B5612 Hard-Shell Medical/SPA Chamber
The HSHMC-B5612 is presented as a hard-shell chamber for institutional, rehabilitation, and spa purchasing discussions. Its linked page describes an aviation-aluminum chamber body and a wide pressure-rated viewing window, which distinguish it from the stainless-steel HP2202 and larger HE5000 Plus options on this page. It remains in the comparison for buyers who prioritize a rigid enclosure and broad visibility but have not yet selected a pressure or capacity.
- Chamber formatHard shell
- Body description on the linked pageAviation aluminum
- Viewing structure on the linked pageWide pressure-rated window
- Configuration classInstitutional, rehabilitation, and SPA chamber
- Confirm in the model data sheetWorking pressure, occupancy, dimensions, system weight, utilities, and included equipment

A MACY-PAN rigid chamber option used to represent a configurable chamber-system purchase.
MACY-PAN Rigid/Soft Hyperbaric Chamber System
This is a series and system-configuration entry, rather than a single model. It is best suited to distributors, project buyers, and OEM customers who need MACY-PAN to narrow both structure and pressure before issuing a model-specific proposal.
- Structure optionsRigid or soft chamber system
- Pressure options represented on the page1.3, 1.5, or 2.0 ATA
- Procurement pathSelect a structure and pressure band first, then receive a named model and data sheet
- Customization focusOEM branding and configuration discussion for projects that have not locked a catalog model

The HB-HOME-S1500 soft chamber shown with its exterior frame, windows, and entry opening.
HB-HOME-S1500 Soft Hyperbaric Chamber
The HB-HOME-S1500 is a soft chamber presented for residential purchasing discussions. Its product page lists 1.3 or 1.5 ATA options, a 2250 mm internal length, a TPU chamber body, and two-way touchscreen control.
- Chamber formatSoft shell
- Rated pressure options shown1.3 or 1.5 ATA
- Internal length shown2250 mm (about 88.6 in)
- Chamber material shownTPU composite
- Control method shownTwo-way touchscreen PLC system
- Selection advantageA long soft chamber format for buyers prioritizing lying space and a lighter structural approach

The MACY-PAN HE5000 Plus multi-person hard-shell chamber with a wide entry and windowed cabin.
MACY-PAN HE5000 Plus Four-Person Hard-Shell Chamber
The HE5000 Plus is a 2.0 ATA hard-shell chamber for four-person capacity. At 850 kg (about 1,874 lb) and 1697 mm (67 in) wide, it requires a delivery route and floor plan sized for a permanent multi-person installation.
- Working pressure2.0 ATA
- CapacityFour people
- Chamber bodyMedical-grade stainless steel
- Dimensions2506 × 1697 × 1741 mm; catalog also lists 99 × 67 × 69 in
- Weight850 kg (about 1,874 lb)
- System arrangementOxygen concentrator, air compressor, and high-efficiency air-cooling system
- Custom optionsInterior layout, color, logo, electric seats, ceiling lighting, and ambient lighting
Check the Site Before You Order
A chamber that fits the treatment or operating plan may still fail the delivery or installation check. Measure the complete route from unloading point to final position, including doors, elevators, stairs, corridors, corners, thresholds, and available rigging space. Compare those measurements with the packaged and installed dimensions, not only the chamber’s internal size.
Confirm the room plan with the model-specific installation instructions:
- Floor loading, level surface, anchoring, and service clearance
- Electrical voltage, frequency, current, grounding, outlets, and backup or safe-shutdown requirements
- Ventilation, temperature, humidity, intake and exhaust clearance, and noise management
- Air compression, oxygen generation or supply, cooling, tubing, and permitted connection methods
- Fire-risk controls, compatible room and chamber materials, prohibited ignition sources, and emergency access
- Continuous observation or communication, alarm audibility, pressure release, and evacuation procedures
- Cleaning materials, cleaning turnover, preventive maintenance access, and storage for approved accessories
Ask the supplier to confirm any site deviation in writing before the purchase order fixes the configuration.
Submit Site MeasurementsBuild a Quote You Can Compare Line by Line
A chamber price is useful only when the equipment and delivery scope are defined. Compare total installed and operating cost under the same working pressure, structure, occupancy, dimensions, destination, installation scope, documentation, and service conditions.
The quote should identify:
- Legal manufacturer, brand, complete model and submodel, equipment condition, and manufacturing location
- Chamber body, compressor, air treatment, oxygen generation or supply, cooling, controls, communications, furniture, accessories, consumables, and spare parts
- Currency, destination, quotation date, validity period, payment milestones, and applicable trade term
- Export packaging, freight, insurance, duties, taxes, customs responsibility, final delivery, indoor handling, installation, commissioning, and acceptance
- Operating and maintenance manuals, safety documents, training, warranty scope, remote support, on-site service, and parts availability
- Estimated production, inspection, shipment, installation, and acceptance milestones, stated as current quote conditions
Verify the Device, Documents, and Acceptance Plan
Shanghai Baobang Medical Equipment Co., Ltd. develops and produces MACY-PAN soft and hard hyperbaric chambers, including single-person and multi-person formats. The purchase file should still connect the exact quoted model to its manufacturer, production configuration, target-market documentation, instructions, and acceptance records.
For a U.S. medical-device purchase, search the FDA database using the manufacturer, device name, model scope, 510(k) number, or product code CBF. Match the result to the intended use and quoted device. Verify any quality-system or product certificate by holder, manufacturing address, standard and version, covered products, issue and expiration dates, and current status.
Agree on acceptance before shipment. The plan should identify the actual device by model and serial number, list the required documents, and define checks for configuration, pressure and relief functions, controls, alarms, communication, air and oxygen systems, leakage, accessories, and safety functions. Record deviations and the corrective action required before final acceptance or use.
Request the Procurement Document ListBuying FAQ
How much does a hyperbaric chamber cost?
MACY-PAN uses a request-for-quote process because the linked options do not share one equipment and delivery scope. The response should give you a named model, configuration list, dated price, validity period, delivery basis, and separately identified installation and service items so you can compare it with another offer.
Should I choose 1.3, 1.5, or 2.0 ATA?
Use 1.3–1.5 ATA options to review the listed soft-chamber range and 2.0 ATA to review the listed HP2202 and HE5000 hard-shell options. That is only a product-routing step; the full comparison above determines whether the structure, intended use, and operating conditions fit.
Can I buy a chamber for residential use?
Start with the exact model’s intended use and instructions, then assess operator supervision, emergency response, delivery access, electrical service, grounding, ventilation, fire safety, communication, and maintenance space. A page label such as “home” or “portable” does not establish that every residence or use is suitable.
Is a chamber listed on the website available for immediate delivery?
Website presence does not establish current inventory or lead time. Ask for a dated written quotation that identifies the model, configuration, production status, inspection plan, shipping method, destination, and delivery conditions.
Tell Us What You Need
Photos or a floor plan can help the team review the delivery route and installation area.
- Phone: 0086-180-1702-3916
- Email: rachel@macypan.com
- WhatsApp: 0086-180-1702-3916
- Address: Bldg.15, No.899 Guinan Rd, Songjiang Dist, Shanghai, China 201617
HBOTSALE