ابحث في المحطة بأكملها

athletes hyperbaric chamber

Compare reclining, seated, and shared-chamber configurations for your training facility or personal setup. MACY-PAN, manufactured by Shanghai Baobang Medical Equipment Co., Ltd., offers soft and hard chambers with different space, pressure, and equipment requirements.

Send your preferred product, room dimensions, and destination to request a configuration-specific quote.

Define the Role in Your Athlete Program

Decide whether the chamber is being considered for general recovery routines or treatment of a diagnosed condition. That decision affects the equipment, clinical supervision, and documentation your project needs.

A 2025 review in Undersea and Hyperbaric Medicine found limited evidence supporting hyperbaric oxygen for recovery in athletes with musculoskeletal injuries or mild traumatic brain injury. Have your sports medicine clinician assess the intended use before selecting pressure, oxygen exposure, or session frequency. Read the athlete-focused review.

Compare Body Position and Space

These listings describe reclining, seated, and shared HE5000 arrangements. Match the quoted unit’s construction and interior layout to how the athlete will enter, sit or lie down, and leave the chamber.

ConfigurationPublished size or capacityWhat to check
Home-use listingSource page: 88.6 in long; 31.5 in diameterConstruction, user position, and entrance design of the quoted unit
Sports listingSource page: 88.6 in long; 35.4 in diameterShell material, entrance design, and usable interior clearance of the quoted unit
Seated listing55.1 × 39.4 × 66.9 in external shellSeat height, legroom, headroom, and the transfer route
HE5000 listingsUp to three people, depending on layoutSeat count, shared pressure schedule, individual oxygen connections, and entry clearance

Published chamber dimensions do not establish usable interior space or the full installed footprint. Request a dimensioned drawing for the selected layout, especially when planning access for a tall athlete or a person with limited mobility.

Explore the Chamber Configurations

These six product listings include three HE5000 packages alongside home-use, seated, and sports configurations. The HE5000 entries share a model family; compare the supplied equipment and approved layout when requesting a quote.

MACY-PAN chamber with a transparent entrance door

جهاز HE5000 Überdruckkammer 2-3 أشخاص

A second HE5000 listing with internal and external touch controls and a published chamber weight of about 1,433 lb. Ask for the approved layout drawing when comparing it with the other HE5000 packages.

  • Maximum listed pressure2.0 ATA
  • السعة المدرجة2–3 أشخاص
  • Listed shell materialفولاذ مقاوم للصدأ 304
  • Listed chamber weightتقريبًا 1,433 رطل (650 كجم)
HE5000 room-type chamber with a broad front window

he5000 (ماسي-بان)

A room-type HE5000 package with dual touchscreens, two 10 L/min oxygen concentrators, and dedicated air conditioning. Its listed 2,600 W system load is relevant when planning power and room cooling.

  • Listed pressure range1.1–2.0 ATA
  • السعة المدرجة1–3 أشخاص
  • Listed gas flow140 L/min air; 20 L/min oxygen
  • Listed electrical load2,600 W; 110/220 V, 50/60 Hz
White home-use oxygen chamber shown from the side

غرفة الأكسجين للاستخدام المنزلي

The page describes a TPU chamber with a zipper entrance, while the supplied image shows a defined door frame and a chair. Confirm the construction, user position, and matching specifications for the unit being quoted.

  • Source-page pressure range1.3–1.5 ATA
  • Source-page chamber dimensions88.6 in long × 31.5 in diameter (225 × 80 cm)
  • Source-page materialTPU composite
  • Source-page electrical load600 W; 110/220 V, 50/60 Hz
Oval seated chamber with an individual chair

حجرة الضغط العالي في وضع الجلوس

An upright aluminum chamber for buyers who prefer a seated position. The listed shell is approximately 55 × 39 × 67 inches; allow additional room for supporting equipment and operator access.

  • Listed pressure range1.3–1.5 ATA
  • Listed shell dimensions55.1 × 39.4 × 66.9 in (140 × 100 × 170 cm)
  • Listed chamber weightApprox. 243 lb (110 kg), excluding peripherals
  • Listed electrical load600 W; 110/220 V, 50/60 Hz
Horizontal chamber with a transparent sliding cover and overhead control screen

كامارا هيبيرباريكا ديبورتي

The product page describes a TPU chamber, while the supplied image shows a rigid-looking shell with a sliding cover. Ask us to confirm the shell material, entrance design, and corresponding dimensions for the unit being quoted.

  • Source-page pressure range1.1–1.5 ATA
  • Source-page chamber dimensions88.6 in long × 35.4 in diameter (225 × 90 cm)
  • Source-page materialTPU composite
  • Source-page air flow70 L/min

Specify Pressure and Oxygen Delivery Together

The listed configurations span pressures up to 1.5 ATA or 2.0 ATA. ATA means atmospheres absolute: it includes normal atmospheric pressure. Confirm the normal working range and maximum permitted pressure for the exact unit you order.

Specify the chamber’s pressurizing gas separately from the oxygen delivered to the user. A concentrator’s stated output purity describes the gas at its outlet; the mask or other approved interface, flow setting, and breathing arrangement determine how it reaches the user.

The room-type HE5000 package lists 20 L/min total oxygen output from two concentrators, while the home-use and seated listings each state 10 L/min. For a shared chamber, request the number of user connections and the flow available at each connection during simultaneous use.

Ask for a configuration list covering the compressor, concentrator or approved oxygen source, cooling, communication system, pressure controls, relief devices, and accessories. This establishes which equipment is included and which services the room must provide.

Plan Delivery, Utilities, and Daily Turnover

Bring the Complete System into the Room

Measure doors, corridors, turns, elevators, and the unloading route. The HE5000 listings include a chamber weight of about 1,433 lb, compared with approximately 243 lb for the seated chamber before peripherals. Have the building’s responsible professional assess floor loading and handling arrangements using the final equipment drawings.

Allow space for the compressor, oxygen equipment, cooling, tubing, service access, and the person supervising operation. The 600 W home-use and seated listings have different electrical loads from the 2,500–2,600 W HE5000 packages. Confirm voltage, frequency, grounding, circuit capacity, ventilation, and heat rejection for the selected system.

Allow Time Between Athletes

Build the booking cycle around preparation, entry, pressurization, the prescribed exposure, decompression, exit, cleaning, and required checks. A chamber’s seat count alone cannot establish the number of athletes you can accommodate each day.

For shared sessions, confirm that every user can follow the same approved pressure schedule and that the staffing plan covers monitoring and emergencies. Separate bookings may be needed when athletes have different clinical or access requirements.

Prepare Staff and the Room Before Operation

High oxygen concentrations increase fire risk. Follow the exact equipment instructions for grounding, permitted clothing and items, cleaning materials, maintenance, and safety checks. Provide trained staff and continuous supervision throughout use. The FDA’s hyperbaric device safety recommendations explain these operating requirements.

Compare the Complete Cost of Ownership

The chamber structure, pressure configuration, seating, oxygen equipment, cooling, and destination all affect the quote. Compare the complete supplied system and delivery scope when evaluating prices.

  • Equipment: chamber, compressor, oxygen equipment, cooling, controls, interfaces, and selected accessories.
  • Delivery: packing dimensions and weight, freight terms, unloading, installation, and commissioning responsibilities.
  • Operation: staff training, consumables, approved cleaning materials, scheduled maintenance, and spare parts.
  • Service: written warranty coverage, exclusions, technical support, and responsibility for on-site work.

For a U.S. project, request the exact manufacturer and model identification, intended-use documentation, and applicable market authorization before ordering. The quoted unit and its documents must correspond.

Include your target purchase date and destination so the quotation can state the production schedule, shipping basis, and service scope for your order.

Request a Quote for Your Selected Chamber

  • الهاتف: 0086-180-1702-3916
  • البريد الإلكتروني: rachel@macypan.com
  • واتساب: 0086-180-1702-3916
  • العنوان: المبنى 15، رقم 899 طريق غينان، منطقة سونغجيانغ، شنغهاي، الصين 201617

Tell us which product interests you, how many people will use it per session, your room and access dimensions, destination, and target purchase date. Include your required pressure and oxygen configuration if your clinical or operating plan already specifies them.

مستودع الشركة التابعة للولايات المتحدة الأمريكية الدعم الفني المحلي بالولايات المتحدة الأمريكية
*
*

بلدك

*
تقديم!
تم التقديم بنجاح!
فشل التقديم
عنوان بريد إلكتروني غير صحيح!
رقم هاتف غير صحيح!

اعثر على غرفة Hbot المناسبة لك

مستودع الشركة التابعة للولايات المتحدة الأمريكية الدعم الفني المحلي بالولايات المتحدة الأمريكية

أخبرنا بما تحتاج إليه. وسنقدم لك توصيات بشأن الطرازات المناسبة والأسعار وخيارات التسليم.

*
*

الشحن إلى:

الولايات المتحدة الأمريكيةكنداأخرى
تقديم!
تم التقديم بنجاح!
فشل التقديم
عنوان البريد الإلكتروني غير صالح!
رقم هاتف غير صحيح!

سيُغلق هذا في 0 ثوانٍ