1.5 غرفة الضغط العالي 1.5 ata
Compare soft, hard-shell, seated, lying, stretcher and multi-person chamber configurations around the 1.5 ATA requirement. Shanghai Baobang Medical Equipment Co., Ltd. manufactures MACY-PAN hyperbaric chamber systems and can prepare a quotation around your target pressure, occupancy, installation conditions and market requirements.
The pressure rating is only one part of the specification. Confirm the shell structure, oxygen source, chamber dimensions, access method, electrical supply, cooling arrangement and required documentation before selecting a model.
1.5 ATA hyperbaric chamber
What 1.5 ATA Specifies
1.5 ATA is an absolute pressure rating. At sea level it is approximately 22.0 psia, or about 7.35 psi above normal atmospheric pressure. The rating describes the total pressure inside the chamber; it does not by itself define the oxygen concentration, breathing interface, clinical protocol or regulatory status.
A purchase specification should state whether 1.5 ATA is a fixed operating point or the upper end of an adjustable range. It should also identify the pressure-control method, relief arrangement and the oxygen-delivery equipment supplied with the chamber.
| Term | What to confirm | Why it matters |
|---|---|---|
| Absolute pressure | 1.5 ATA is about 22.0 psia | Prevents confusion between absolute and gauge pressure |
| Gauge pressure | About 7.35 psig at sea level | Supports comparison with gauges and technical documents |
| Working range | Fixed 1.5 ATA or adjustable below 1.5 ATA | Affects controls, operating procedure and quotation |
| Oxygen delivery | Concentrator output, breathing interface and supplied accessories | Pressure and oxygen supply are separate specifications |
Choose the Chamber Configuration First
Start with the user's position, required access and available room. These decisions narrow the field faster than comparing pressure alone.
Portable lying soft chamber
Suited to a reclining layout where low chamber weight and storage flexibility are priorities. MACY-PAN ST801 and ST901 specifications include 1.5 ATA options; verify diameter, occupancy and the equipment package for the selected version.
Portable seated soft chamber
Supports an upright or reclined sitting position. L1, ST1700 and ST2200 specifications include 1.5 ATA options, with different footprints and occupancy arrangements.
Hard-shell monoplace chamber
Provides a rigid chamber body and a defined installation footprint. The HP1501 line is specified at 1.5 or 1.6 ATA and is available in several diameters; confirm door clearance, system weight and power before ordering.
Stretcher or multi-person chamber
Prioritizes assisted entry, larger access or more than one occupant. The MC750 page specifies a stretcher layout around 1.5 ATA, while HE5000 pages in the supplied list include higher-pressure multi-person configurations that require separate confirmation.
Specified Product and Selection Pages
These six entries preserve the exact links, images and order supplied for this page. Review the pressure line on each card: the list includes 1.5 ATA options, broader selection pages and higher-pressure HE5000 references.

HE5000 2–3 Person Hyperbaric Chamber
A hard-shell multi-person chamber page for buyers comparing higher-capacity systems. This supplied entry is a 2.0 ATA reference rather than a 1.5 ATA model.
- الضغط2.0 ATA page specification
- السعة2–3 people
- StructureHard-shell multi-person chamber

1.3–1.5 ATA Hyperbaric Chamber Range
A range page covering portable lying and seated soft chambers plus rigid chamber options. Use it to compare form factor before requesting an exact model quotation.
- نطاق الضغطIncludes 1.3–1.5 ATA options
- FormatsLying, seated and hard-shell lines
- SupplyOEM configuration available

HE5000 2–3 Person Hyperbaric Chamber
A second supplied HE5000 page and image pairing for the 2–3 person hard-shell chamber. It is retained separately because the source list specifies both entries.
- الضغط2.0 ATA page specification
- السعة2–3 people
- AccessWalk-in hard-shell layout

Hyperbaric Chamber Manufacturer and OEM Supply
A manufacturer overview for buyers evaluating soft- and hard-shell chamber production, product range and OEM cooperation.
- SupplierShanghai Baobang Medical Equipment Co., Ltd.
- Product scopeSoft- and hard-shell chamber systems
- CooperationOEM and ODM services

MC750 1.5 ATA Stretcher Hyperbaric Chamber
A stretcher-entry chamber designed around assisted access. The supplied page lists a 750 mm chamber diameter and a 1.5 ATA working configuration.
- ضغط العمل1.5 ATA
- Chamber diameter750 مم
- EntrySliding stretcher layout

دليل اختيار غرفة الأكسجين للاستخدام المنزلي
A selection page for comparing portable and rigid chamber formats intended for home-use planning. Confirm the exact model, supervision, site and market requirements before ordering.
- RangeIncludes 1.3–1.5 ATA home-use options
- FormatsPortable soft and rigid chamber choices
- Selection basisSpace, access, power and operating plan
Information Needed for an Accurate Quotation
A comparable quotation identifies the chamber, the supporting equipment and the delivery boundary. Send the following inputs together so the supplier can select a configuration without assuming site conditions.
| Input | Details to provide | Quotation impact |
|---|---|---|
| Pressure requirement | Required working ATA and whether adjustability is needed | Chamber line, controls and relief configuration |
| User and access | Occupancy, sitting or lying position, assisted entry or stretcher access | Chamber geometry, door and internal layout |
| Available space | Room dimensions, door width, route to the room and maintenance clearance | Model fit, delivery plan and installation work |
| Utilities | Voltage, frequency, outlet capacity, ventilation and ambient conditions | Electrical version, cooling and auxiliary equipment |
| Supply scope | Compressor, oxygen concentrator, cooling, furniture, accessories and spares | Prevents incomplete equipment-only price comparisons |
| Destination market | Country, intended setting and required documents | Documentation, labeling, electrical version and project review |
| Branding and quantity | Order volume, logo, color, language and packaging requests | OEM work, unit cost and production schedule |
Plan the Site and Operating Routine
Installation and daily operation depend on the exact chamber and equipment package. Review the manufacturer's manual and the rules that apply at the destination before commissioning.
Delivery and room access
Measure the entire path from the unloading point to the installation position. Record doorways, corners, elevators, floor loading and the clearance required to open the chamber and service the equipment.
Electrical and ventilation
Confirm voltage, frequency, circuit capacity, plug type and room ventilation. Compression equipment produces heat, so cooling and free airflow around the system must be included in the site plan.
Pre-use checks
Inspect the chamber body, windows, seals or zippers, hoses, pressure-relief devices, gauges and communication arrangements before use. Resolve leaks, damage or abnormal readings before pressurization.
Controlled pressurization
Use the operating procedure supplied for the selected model. The operator should monitor pressure, the occupant and the equipment throughout pressurization, the session and depressurization.
Manufacturer and OEM Options
Shanghai Baobang Medical Equipment Co., Ltd. develops and manufactures MACY-PAN soft- and hard-shell hyperbaric chambers in Shanghai, China. The 2026 product information records 19 years of industry experience and supply to more than 123 countries and regions.
OEM and ODM services can cover chamber color, product logo and interface language. Product-specific options differ: soft chamber lines may offer red-light configurations, HP1501 and HP2202 lines may support control-panel customization, and HE5000 configurations may offer interior options such as powered seating and lighting. Confirm each option against the selected model and destination requirements before it is added to the order.
Discuss OEM Requirements1.5 ATA Chamber Questions
Is 1.5 ATA the same as 1.5 psi?
No. ATA is absolute pressure. At sea level, 1.5 ATA is about 22.0 psia, which is approximately 7.35 psi above ambient pressure.
Does a 1.5 ATA rating define the oxygen concentration?
No. The chamber pressure and the oxygen-delivery system are separate specifications. Confirm concentrator output, breathing interface and the exact supplied equipment.
Which MACY-PAN lines include a 1.5 ATA option?
The supplied product information lists 1.5 ATA options in portable lying models such as ST801 and ST901, portable seated models such as L1, ST1700 and ST2200, and the HP1501 hard-shell line. The MC750 page also presents a 1.5 ATA stretcher configuration. Confirm the current build sheet for the exact model ordered.
Why are 2.0 ATA HE5000 pages included in this list?
They are part of the exact source list supplied for this page and show higher-capacity alternatives. Their pressure specification should not be treated as 1.5 ATA; request a separate HE5000 configuration review if that format is relevant.
What should I send with an inquiry?
Provide the target pressure, number of users, preferred posture and access method, room and delivery-path dimensions, electrical supply, destination country, required documents, quantity and any OEM requests.
Request a 1.5 ATA Chamber Quote
- Phone: 0086-180-1702-3916
- Email: rachel@macypan.com
- WhatsApp: 0086-180-1702-3916
- Address: Bldg.15, No.899 Guinan Rd, Songjiang Dist, Shanghai, China 201617
HBOTSALE