Search the whole station

2.0 ATA Hyperbaric Chamber For Sale Support Customization

MACY-PAN HE5000 is the 1 hardware hyperbaric oxygen chamber specially designed for medical institutions. It provides stable 2.0 ATA treatment pressure and spacious 3-person cockpit space. It integrates intelligent touch control system, red light therapy and negative ion purification functions. It is an ideal choice to improve clinical rehabilitation efficiency and accept large orders.

2.0 ATA Hyperbaric Chamber For Sale Support Customization

gear

The HE5000 system provides a stable working environment with a maximum 2.0 ATA (atmospheric pressure) through a fully enclosed hardware structure. Compared with ordinary 1.3 ATA software capsule, 2.0 ATA pressure can increase the dissolved oxygen content in plasma by more than 3 times, significantly accelerating postoperative wound healing and nervous system repair.

gear

The size of the cabin reaches 208cm (length) x 163cm (width) x 175cm (height), and the internal space is about 5.6 cubic meters. This upright walking design allows patients to enter and exit without bending down, and supports 3 adults to treat at the same time, greatly increasing the number of visits per unit time in the clinic.

gear

Equipped with high-resolution external and internal dual touch screen, can accurately adjust the pressure value, treatment time and cabin lighting. The system has built-in data recording function, which can automatically monitor the oxygen concentration and pressure changes in the cabin, and the operation error is controlled within 0.01 ATA to ensure the absolute safety of the treatment process.

gear

The top of the cabin integrates a professional-grade red light therapy module (660nm wavelength), which promotes mitochondrial cell regeneration while inhaling oxygen. With the air purification system that releases 5 million negative ions per cubic centimeter, it can effectively settle the dust in the cabin and provide a sterile and fresh treatment environment.

gear

The standard includes two 10L medical-grade oxygen generators, an oil-free silent air compressor and a special air conditioning system. The unit can maintain the oxygen purity in the cabin at the 93%±3% standard level within 15 minutes, and at the same time control the temperature in the cabin to 20-26 degrees Celsius through the air conditioning system, which solves the problem of sultry summer.

gear

The safety system includes automatic and manual double insurance. When the cabin pressure exceeds 10% of the preset value, the safety valve will automatically open the pressure relief. In addition, there are emergency stop buttons and manual pressure relief valves inside and outside the cabin to ensure that patients can safely leave the cabin within 1 minute in case of power failure or emergency.

Parameter categoriesDetailed Specifications
Product ModelHE5000 (MACY-PAN)
hull typeHard Shell Room Type
Work pressure1.1 ATA – 2.0 ATA (Adjustable)
cabin dimensions208cm (L) x 163cm (W) x 175cm (H) (82″ x 64″ x 69″)
cabin weightApproximately 650 kg (1433 lbs)
Oxygen purity93% ± 3%
airflow140 L/min (air) + 20 L/min (oxygen)
Main materialsHigh-strength 304 stainless steel + aerospace-grade polycarbonate window
Rated power2600W (complete system)
Operating noise< 50dB (Low noise, quiet design)
Additional featuresRed light therapy, negative ion system, RGB ambient lighting, Bluetooth speaker
Voltage SpecificationsAC 110V/220V, 50Hz/60Hz

For medical institutions seeking efficient treatment, the HE5000 hardware cabin in the category of 2.0 ata hyperbaric chamber has a decisive advantage over traditional software cabins. The HE5000 uses a rigid stainless steel structure that can withstand pressure loads much higher than the soft compartment (usually limited to 1.5 ATA), achieving true 2.0 ATA medical-grade pressurization. This high-pressure environment is essential for the treatment of intractable wounds, sudden deafness and severe sports injuries, which are often areas of treatment beyond the reach of low-pressure capsules. In addition, the HE5000’s “room-type” design revolutionizes the user experience of hyperbaric oxygen therapy. Traditional single lying pods often leave patients feeling claustrophobic and unable to read or use electronic devices during treatment. The HE5000 provides an upright space similar to a small lounge, with an oversized transparent window, completely eliminating claustrophobia. Its built-in air conditioning and entertainment system makes the 60-90 minute treatment process comfortable and easy to adhere to, greatly improving the repurchase rate and satisfaction of patients.

2.0 ATA Hyperbaric Chamber Comparison Points
solution

MACY-PAN wide-angle panoramic window design

In view of the problem that many patients are prone to anxiety and claustrophobia in closed spaces, MACY-PAN designed a 3 super-sized aviation-level transparent window to provide an open visual experience and reduce the psychological pressure of patients by 90%.
solution

MACY-PAN intelligent constant temperature circulation system

In view of the problem that patients sweat and collapse caused by the temperature rise in the cabin during long-term high-pressure treatment, the MACY-PAN integrates a customized water-cooled air conditioning system to ensure that the cabin is always cool and dry, and to avoid discomfort caused by sultry heat.
solution

MACY-PAN automatic boost control algorithm

In view of the problem that manual pressure adjustment is easy to cause eardrum barotrauma, the MACY-PAN has developed an intelligent linear booster program, which can automatically pressurize at a gentle rate of 0.1 ATA per minute, effectively eliminating 95% of ear discomfort.

Specialized Rehabilitation Physiotherapy and Orthopedics Center

For patients with postoperative recovery and fracture rehabilitation crowd. 2.0 ATA’s high-pressure environment can significantly increase the blood oxygen supply at the fracture site, accelerate the formation of callus, effectively reduce postoperative edema and inflammatory reaction, and shorten the hospitalization rehabilitation period by more than 30%.

Specialized Rehabilitation Physiotherapy and Orthopedics Center

High-end medical beauty and anti-aging clinic

For high net worth customers who are concerned about skin condition and systemic anti-aging. Hyperbaric oxygen can activate skin collagen regeneration, reduce wrinkles, while the red light treatment function can be synergistic, improve sleep quality, is currently the core of the top anti-aging treatment auxiliary equipment.

High-end medical beauty and anti-aging clinic

Professional sports teams and training bases

For professional athletes who need a quick physical recovery. Lactic acid accumulation and micro-damage after high-intensity training can be quickly cleared by hyperbaric oxygen therapy. The multiplayer cabin design allows team members to perform recovery therapy at the same time, improving the overall training turnover efficiency of the team.

Professional sports teams and training bases

Brain Health and Neurological Junior College Institutions

For stroke sequelae, autistic children or people with cognitive impairment. High concentrations of dissolved oxygen can penetrate the blood-brain barrier, improve brain hypoxia, activate dormant nerve cells, and provide the necessary physiological basis for the functional recovery of the nervous system.

Brain Health and Neurological Junior College Institutions
011

After the power is connected, turn on the air conditioner and oxygen generator to preheat for 2 minutes, and check whether the sealing strip of the compartment door is intact and free of foreign matters. Assist the patient to enter the cabin and wear the oxygen mask. Make sure that the door is fully closed and locked. Make sure that the current set pressure is 2.0 ATA through the touch screen.

022

Click the “Start” button on the control panel, and the system will automatically start the air compressor to pressurize. At this time, the patient should be reminded to swallow or pinch the nose to pump air to balance the ear pressure, and observe that the pressure value on the screen rises steadily at a rate of 0.1 ATA per minute until it reaches the preset pressure.

033

When the pressure reaches 2.0 ATA, the system will automatically stop the pressure and enter the steady pressure oxygen phase. At this time, the patient inhales high-purity oxygen through a mask. The operator can maintain communication with the patient in the cabin through an external intercom and confirm the patient’s status through the window. The treatment usually lasts 60 to 90 minutes.

044

After the treatment is over, click the “Stop” or “Decompression” button, and the system will slowly release the pressure through the silencer exhaust valve. The decompression process usually takes 10 to 15 minutes to prevent the risk of decompression sickness. When the pressure displayed on the screen returns to zero and the soft door can be easily pushed open, the patient can be assisted to exit the cabin.

CERTIFICATE

factory pic3

Welcome to our Frequently Asked Questions page. We have compiled answers to common questions you may have, hoping to provide you with clear and quick solutions. If you cannot find the information you need here, please feel free to contact our customer support team.

Is the HE5000 2.0 ATA pressure suitable for all patients?
2.0 ATA falls within the mild medical stress range and is suitable for most people seeking rehabilitation, anti-aging and motor recovery. However, for patients with untreated pneumothorax, severe emphysema, or recent ear surgery, it must be evaluated under the guidance of a professional doctor before use.
What are the specific requirements for the installation of this equipment?
Due to the large size of the cabin and the weight of 650kg, the installation site needs to be located on the 1 floor or the floor with a load-bearing elevator. The room area is recommended to be at least 3 meters x 4 meters, and good ventilation and heat dissipation conditions are required. The power supply shall be equipped with independent 220V or 110V grounding socket, and the bearing power shall not be less than 3000W.
Can the red light therapy and negative ion functions in the cabin be turned off separately?
You can. The MACY-PAN intelligent control system allows the user to control each function independently. According to the needs of the patient, you can turn on or off the red light therapy lamp, negative ion generator and atmosphere light individually through the touch screen in the cabin.
How is the oxygen concentration of HE5000 guaranteed?
The system is equipped with two industrial-grade 10L oxygen generators as oxygen sources, and adopts double-tower PSA pressure swing adsorption technology to ensure continuous output of high-concentration oxygen with a purity of 93%±3%. It is recommended to test or replace the molecular sieve of the oxygen generator every 5000 hours of cumulative use.
What if there is a sudden power failure during treatment?
The HE5000 is designed with a power failure safety protection mechanism. Once the power is cut off, the intake valve will automatically close to maintain the cabin pressure without sudden drop. The operator can rotate the external manual pressure relief valve to release the pressure safely at a controlled speed. The whole process does not require power support to ensure the safe exit of personnel.
What is the warranty policy and maintenance cycle of the equipment after purchase?
The whole machine usually enjoys 1 to 2 years of warranty service (subject to the contract). Routine maintenance is very simple. It only needs to clean the air compressor intake filter screen every 6 months, and regularly wipe the interior of the cabin with a neutral detergent. There is no need to add oil because it uses oil-free compressor technology.
E-mail*
Number
Country
Name
Your Question
Submitting!
Success!
Submission failed! Please try again later!
Email format error!
Format error!

2.0 ATA Hyperbaric Chamber For Sale Support Customization

MACY-PAN HE5000 is the 1 hardware hyperbaric oxygen chamber specially designed for medical institutions. It provides stable 2.0 ATA treatment pressure and spacious 3-person cockpit space. It integrates intelligent touch control system, red light therapy and negative ion purification functions. It is an ideal choice to improve clinical rehabilitation efficiency and accept large orders.

2.0 ATA Hyperbaric Chamber For Sale Support Customization

gear

The HE5000 system provides a stable working environment with a maximum 2.0 ATA (atmospheric pressure) through a fully enclosed hardware structure. Compared with ordinary 1.3 ATA software capsule, 2.0 ATA pressure can increase the dissolved oxygen content in plasma by more than 3 times, significantly accelerating postoperative wound healing and nervous system repair.

gear

The size of the cabin reaches 208cm (length) x 163cm (width) x 175cm (height), and the internal space is about 5.6 cubic meters. This upright walking design allows patients to enter and exit without bending down, and supports 3 adults to treat at the same time, greatly increasing the number of visits per unit time in the clinic.

gear

Equipped with high-resolution external and internal dual touch screen, can accurately adjust the pressure value, treatment time and cabin lighting. The system has built-in data recording function, which can automatically monitor the oxygen concentration and pressure changes in the cabin, and the operation error is controlled within 0.01 ATA to ensure the absolute safety of the treatment process.

gear

The top of the cabin integrates a professional-grade red light therapy module (660nm wavelength), which promotes mitochondrial cell regeneration while inhaling oxygen. With the air purification system that releases 5 million negative ions per cubic centimeter, it can effectively settle the dust in the cabin and provide a sterile and fresh treatment environment.

gear

The standard includes two 10L medical-grade oxygen generators, an oil-free silent air compressor and a special air conditioning system. The unit can maintain the oxygen purity in the cabin at the 93%±3% standard level within 15 minutes, and at the same time control the temperature in the cabin to 20-26 degrees Celsius through the air conditioning system, which solves the problem of sultry summer.

gear

The safety system includes automatic and manual double insurance. When the cabin pressure exceeds 10% of the preset value, the safety valve will automatically open the pressure relief. In addition, there are emergency stop buttons and manual pressure relief valves inside and outside the cabin to ensure that patients can safely leave the cabin within 1 minute in case of power failure or emergency.

Parameter categoriesDetailed Specifications
Product ModelHE5000 (MACY-PAN)
hull typeHard Shell Room Type
Work pressure1.1 ATA – 2.0 ATA (Adjustable)
cabin dimensions208cm (L) x 163cm (W) x 175cm (H) (82″ x 64″ x 69″)
cabin weightApproximately 650 kg (1433 lbs)
Oxygen purity93% ± 3%
airflow140 L/min (air) + 20 L/min (oxygen)
Main materialsHigh-strength 304 stainless steel + aerospace-grade polycarbonate window
Rated power2600W (complete system)
Operating noise< 50dB (Low noise, quiet design)
Additional featuresRed light therapy, negative ion system, RGB ambient lighting, Bluetooth speaker
Voltage SpecificationsAC 110V/220V, 50Hz/60Hz

2.0 ATA Hyperbaric Chamber Comparison Points

2.0 ATA Hyperbaric Chamber Comparison Points
solution
MACY-PAN wide-angle panoramic window design
In view of the problem that many patients are prone to anxiety and claustrophobia in closed spaces, MACY-PAN designed a 3 super-sized aviation-level transparent window to provide an open visual experience and reduce the psychological pressure of patients by 90%.
solution
MACY-PAN intelligent constant temperature circulation system
In view of the problem that patients sweat and collapse caused by the temperature rise in the cabin during long-term high-pressure treatment, the MACY-PAN integrates a customized water-cooled air conditioning system to ensure that the cabin is always cool and dry, and to avoid discomfort caused by sultry heat.
solution
MACY-PAN automatic boost control algorithm
In view of the problem that manual pressure adjustment is easy to cause eardrum barotrauma, the MACY-PAN has developed an intelligent linear booster program, which can automatically pressurize at a gentle rate of 0.1 ATA per minute, effectively eliminating 95% of ear discomfort.

Specialized Rehabilitation Physiotherapy and Orthopedics Center

For patients with postoperative recovery and fracture rehabilitation crowd. 2.0 ATA’s high-pressure environment can significantly increase the blood oxygen supply at the fracture site, accelerate the formation of callus, effectively reduce postoperative edema and inflammatory reaction, and shorten the hospitalization rehabilitation period by more than 30%.

Specialized Rehabilitation Physiotherapy and Orthopedics Center

High-end medical beauty and anti-aging clinic

For high net worth customers who are concerned about skin condition and systemic anti-aging. Hyperbaric oxygen can activate skin collagen regeneration, reduce wrinkles, while the red light treatment function can be synergistic, improve sleep quality, is currently the core of the top anti-aging treatment auxiliary equipment.

High-end medical beauty and anti-aging clinic

Professional sports teams and training bases

For professional athletes who need a quick physical recovery. Lactic acid accumulation and micro-damage after high-intensity training can be quickly cleared by hyperbaric oxygen therapy. The multiplayer cabin design allows team members to perform recovery therapy at the same time, improving the overall training turnover efficiency of the team.

Professional sports teams and training bases

Brain Health and Neurological Junior College Institutions

For stroke sequelae, autistic children or people with cognitive impairment. High concentrations of dissolved oxygen can penetrate the blood-brain barrier, improve brain hypoxia, activate dormant nerve cells, and provide the necessary physiological basis for the functional recovery of the nervous system.

Brain Health and Neurological Junior College Institutions
011

After the power is connected, turn on the air conditioner and oxygen generator to preheat for 2 minutes, and check whether the sealing strip of the compartment door is intact and free of foreign matters. Assist the patient to enter the cabin and wear the oxygen mask. Make sure that the door is fully closed and locked. Make sure that the current set pressure is 2.0 ATA through the touch screen.

022

Click the “Start” button on the control panel, and the system will automatically start the air compressor to pressurize. At this time, the patient should be reminded to swallow or pinch the nose to pump air to balance the ear pressure, and observe that the pressure value on the screen rises steadily at a rate of 0.1 ATA per minute until it reaches the preset pressure.

033

When the pressure reaches 2.0 ATA, the system will automatically stop the pressure and enter the steady pressure oxygen phase. At this time, the patient inhales high-purity oxygen through a mask. The operator can maintain communication with the patient in the cabin through an external intercom and confirm the patient’s status through the window. The treatment usually lasts 60 to 90 minutes.

044

After the treatment is over, click the “Stop” or “Decompression” button, and the system will slowly release the pressure through the silencer exhaust valve. The decompression process usually takes 10 to 15 minutes to prevent the risk of decompression sickness. When the pressure displayed on the screen returns to zero and the soft door can be easily pushed open, the patient can be assisted to exit the cabin.

Know Us and Contact Us

*
Submitting!
Success!
Submission failed! Please try again later!
Email format error!
Format error!

FAQ

Is the HE5000 2.0 ATA pressure suitable for all patients?
2.0 ATA falls within the mild medical stress range and is suitable for most people seeking rehabilitation, anti-aging and motor recovery. However, for patients with untreated pneumothorax, severe emphysema, or recent ear surgery, it must be evaluated under the guidance of a professional doctor before use.
What are the specific requirements for the installation of this equipment?
Due to the large size of the cabin and the weight of 650kg, the installation site needs to be located on the 1 floor or the floor with a load-bearing elevator. The room area is recommended to be at least 3 meters x 4 meters, and good ventilation and heat dissipation conditions are required. The power supply shall be equipped with independent 220V or 110V grounding socket, and the bearing power shall not be less than 3000W.
Can the red light therapy and negative ion functions in the cabin be turned off separately?
You can. The MACY-PAN intelligent control system allows the user to control each function independently. According to the needs of the patient, you can turn on or off the red light therapy lamp, negative ion generator and atmosphere light individually through the touch screen in the cabin.
How is the oxygen concentration of HE5000 guaranteed?
The system is equipped with two industrial-grade 10L oxygen generators as oxygen sources, and adopts double-tower PSA pressure swing adsorption technology to ensure continuous output of high-concentration oxygen with a purity of 93%±3%. It is recommended to test or replace the molecular sieve of the oxygen generator every 5000 hours of cumulative use.
What if there is a sudden power failure during treatment?
The HE5000 is designed with a power failure safety protection mechanism. Once the power is cut off, the intake valve will automatically close to maintain the cabin pressure without sudden drop. The operator can rotate the external manual pressure relief valve to release the pressure safely at a controlled speed. The whole process does not require power support to ensure the safe exit of personnel.
What is the warranty policy and maintenance cycle of the equipment after purchase?
The whole machine usually enjoys 1 to 2 years of warranty service (subject to the contract). Routine maintenance is very simple. It only needs to clean the air compressor intake filter screen every 6 months, and regularly wipe the interior of the cabin with a neutral detergent. There is no need to add oil because it uses oil-free compressor technology.
CERTIFICATE