The ST801 configuration is a one-person, lying-type flexible chamber operating at 1.3 ATA absolute pressure. Its 220 × 80 cm TPU cabin works with a separate compressor, oxygen concentrator, and air cooler, giving buyers a compact complete system for indoor personal, fitness, or professionally supervised use where local rules permit.

  • Working Pressure1.3 ATA absolute
  • Cabin Size220 × 80 cm
  • Chamber MaterialTPU flexible envelope
  • User FormatOne-person lying type
  • Minimum Order1 complete set
  • CustomizationColor, logo, language, red-light option

PRESSURE INTERPRETATION

1.3 ATA Means About 30 kPa Above Ambient Pressure

Absolute and gauge pressure use different zero points, so the same operating condition can be described in two ways.

For this model, 1.3 ATA is the absolute chamber pressure and is approximately 30 kPa or 4.4 psi above ambient pressure.

Absolute Pressure1.3 ATA
Gauge Pressure≈30 kPa / 4.4 psi

ROOM PLANNING

The Complete System Needs Ventilation, Power, And Service Access

The cabin footprint alone does not describe the installation area because the compressor, concentrator, cooler, hoses, and operator also need space.

A dry, ventilated room with a grounded outlet, clear equipment airflow, unobstructed hose routing, and access around the zipper supports safer setup and routine service.

  • Equipment airflow remains clear at compressor, concentrator, and cooler inlets and outlets.
  • A grounded outlet matches the ordered equipment voltage.
  • Service access remains available around the zipper, valves, gauges, hoses, and emergency controls.
  • The room excludes ignition sources, prohibited electronics, oils, and static-generating materials.

STANDARD PACKAGE

A Complete ST801 Package Includes The Chamber And Three System Units

Comparing chamber-only prices with complete-system quotations can hide the equipment needed to pressurize, cool, and supply the breathing interface.

The standard quotation covers one chamber cabin, one air compressor, one oxygen concentrator, one air cooler, connection hoses, and the operating accessories stated on the order.

Chamber And Pressure Unit

The TPU cabin and air compressor create and maintain the specified 1.3 ATA chamber pressure.

Oxygen And Breathing Interface

The concentrator and ordered headset, mask, or cannula provide the breathing-gas connection described in the operating instructions.

Cooling And Connection Kit

The air cooler, hoses, valves, gauges, and accessories complete the working system.

PRODUCT PHOTOS

Product Views Show The Flexible Cabin And Supporting Equipment

The retained images cover the chamber exterior, access area, system equipment, and production context used to prepare the quotation.

COMPLETE SPECIFICATIONS

ST801 Specifications Define The 1.3 ATA Configuration

These values keep the quotation, order record, system package, and Product Schema aligned to one configuration.

Product Name1.3 ATA Hyperbaric Chamber
ModelST801
Product CategoryPortable lying-type flexible hyperbaric chamber
Working Pressure1.3 ATA absolute
Cabin Size2200 mm long × 800 mm diameter
Chamber MaterialTPU flexible pressure envelope
System ConfigurationChamber, air compressor, oxygen concentrator, and air cooler
Oxygen Concentrator Output93%+ at the equipment outlet
Chamber Weight13 kg
Nominal System Noise45 dB maximum
CustomizationColor, logo, language, and compatible red-light option
Order Unit1 complete set per shipment

APPLICATIONS AND EQUIPMENT

The ST801 Fits Controlled Indoor Use In Three Main Settings

The same chamber format can serve different operating environments, but room safety, supervision, labeling, and local authorization still govern use.

01

Personal Indoor Installations

The compact one-person lying format fits a dry, ventilated room with enough access for the cabin and separate system units. Operation follows the supplied manual and local rules.

02

Fitness And Recovery Facilities

The flexible cabin can support scheduled, supervised sessions when staff can monitor pressure, airflow, user communication, and post-session cleaning.

03

Small Clinics And Professional Practices

Facilities can evaluate the ST801 where a low-pressure flexible format matches the intended use, operator training, room safety plan, and local authorization.

DIMENSIONS AND TECHNICAL DRAWING

The 2200 × 800 mm Cabin Sets The Main Room-Fit Envelope

The dimensional reference supports room planning before the order-specific drawing fixes connection positions and service clearance.

ST801 1.3 ATA hyperbaric chamber dimensional reference drawing

Room-Fit Dimensions And Connection Planning

The dimensional reference identifies the 2200 mm cabin length, 800 mm diameter, hose routing, and access clearance that affect room fit. The order-specific drawing remains the governing document for connection positions and final installation clearance.

  • Zipper access remains available along the chamber and at both ends.
  • Hose routing avoids sharp bends and trip hazards.
  • System-unit airflow remains clear for cooling and service.
  • The installation supply matches the ordered electrical voltage.

MATERIALS AND MANUFACTURING

TPU Construction Keeps The ST801 Flexible And Portable

The pressure envelope, welded seams, zipper assembly, valves, and viewing panels work as one reusable flexible chamber.

TPU Pressure Envelope

The ST801 uses a flexible TPU cabin with transparent viewing panels and a 13 kg chamber weight.

Welded Seams And Sealing Hardware

High-frequency welded panels, the zipper, valves, hoses, and gauges form the pressure boundary and service connections.

Cleanable External Surfaces

Smooth TPU surfaces and removable interior accessories support routine wiping with manufacturer-approved cleaning products.

PERFORMANCE AND WORKING CONDITIONS

The 1.3 ATA Setting Depends On Stable Airflow And A Clear Safety Boundary

The chamber, compressor, concentrator, and cooler must operate together within the labeled pressure and indoor-environment limits.

1.3 ATARated absolute working pressure
93%+Concentrator output at the equipment outlet
≤45 dBNominal system noise
13 kgChamber cabin weight
Pressurizing MediumAmbient air
Indoor Ambient Range10–30 °C
Working Pressure1.3 ATA absolute / about 30 kPa gauge
Installation BoundaryDry, ventilated, grounded, ignition-controlled area

CUSTOMIZATION

Color, Labels, Language, And Accessories Can Follow The Order

The base ST801 dimensions and 1.3 ATA pressure remain fixed while appearance, labeling, selected accessories, and packing can be quoted.

  • Cabin Color
    Blue, red, white, gray, or a quoted custom color.
  • Logo And Labels
    Exterior logo, operating labels, and language can be adapted for the order.
  • Red-Light Option
    A compatible red-light configuration can be added to the quoted package.
  • Breathing Interface
    Headset, mask, or nasal-cannula package selected for the operating protocol.
  • Packing And Documents
    Export packing, private labeling, and order documents aligned before production.
  • Price And Lead-Time Effect
    Custom work can change price and lead time; the approved order specification controls production.

USE AND SAFETY INSTRUCTIONS

Operate The Chamber Within Its Labeled Pressure And Safety Controls

The operating sequence keeps room preparation, connection checks, monitoring, decompression, cleaning, and storage tied to the supplied system.

01

Prepare The Room And System

Place the chamber and equipment in a dry, ventilated area. Keep cooler and compressor air paths open, use a grounded outlet, and remove ignition sources and prohibited electrical items.

02

Connect And Check Before Entry

Match every hose to its labeled port, inspect the zipper and valves, start airflow, and confirm that inside and outside pressure indications return to ambient before entry.

03

Pressurize Gradually And Monitor

Operate only at the 1.3 ATA setting for this configuration. Maintain communication, monitor comfort and pressure, and stop the session if equalization, airflow, power, or communication becomes abnormal.

04

Depressurize, Clean, And Store

Return fully to ambient pressure before opening. Wipe approved surfaces, dry removable items, inspect filters and hoses, and store the empty chamber away from heat, sharp objects, and direct sunlight.

Fire, Pressure, And Supervision SafetyFollow the exact device instructions, destination-market rules, and trained-professional guidance. High oxygen concentrations increase fire risk. Keep ignition sources, oils, non-approved electronics, and static-generating materials outside; use compatible clothing and never exceed the labeled pressure.

PURCHASING CONDITIONS

One-Set Orders Start At 7–12 Working Days

The quotation separates the complete system, custom options, freight, payment schedule, and destination costs.

  • Minimum Order1 complete set
  • One-Set EvaluationA one-set order is available for evaluation or initial deployment.
  • Standard Lead Time7–12 working days for a standard configuration.
  • Bulk Lead Time15–25 working days after specification and payment approval.
  • Price BasisQuoted in USD on EXW or FOB terms; freight and destination charges are itemized separately.
  • PackingProtected chamber bag plus reinforced export packing for the compressor, concentrator, cooler, hoses, and accessories.
  • Payment Terms30% deposit with the balance due before shipment.
  • Shipping SupportCourier, air, or sea freight can be quoted according to shipment size and destination.

PRE-SALES AND AFTER-SALES SERVICE

Support Covers Specification, Production, Setup, And Repeat Supply

Each stage follows the exact ordered model, accessories, labels, packing, and destination requirements.

Before Ordering: System And Room Review

The quotation review covers model, pressure, room access, electrical supply, accessory package, destination requirements, and intended operating environment.

During Production: Order And Function Checks

The order record tracks the approved color, logo, language, accessory list, packing marks, and pre-shipment function checks.

After Delivery: Setup And Troubleshooting

Remote setup guidance covers hose connections, leak checks, pressure controls, routine cleaning, consumables, and troubleshooting for the supplied system.

FACTORY AND MANUFACTURER

Shanghai Baobang Supplies The Chamber As A Complete Export System

The quotation ties the chamber, system units, accessories, labels, documents, and packing to one order specification.

Shanghai Baobang hyperbaric chamber production area

Shanghai Baobang Medical Equipment Co., Ltd

Based in Songjiang, Shanghai, the manufacturer supplies flexible and hard-shell hyperbaric chamber systems and supports color, logo, language, and selected accessory customization for export orders.

  • Complete chamber, compressor, concentrator, cooler, and hose package
  • Order-specific color, logo, language, and accessory options
  • Pre-shipment function checks and packing-list control
  • Remote setup guidance and repeat-order support

REQUEST A TECHNICAL QUOTE

Share The Room, Voltage, Quantity, And Destination

The quotation can then align the ST801 system package, customization, packing, freight basis, and lead time.

  • Phone: 0086-180-1702-3916
  • Email: rachel@macypan.com
  • WhatsApp: 0086-180-1702-3916
  • Address: Bldg. 15, No. 899 Guinan Rd, Songjiang Dist., Shanghai, China 201617

By submitting, you ask Shanghai Baobang Medical Equipment Co., Ltd to contact you about this product request.

U.S. Subsidiary’s Warehouse USA Local Technical Support
*
*

Your Country

*
Submitting!
Submission successful!
Submission failed!
Incorrect email address!
Incorrect phone number!

Find Right Hbot Chamber For You

U.S. Subsidiary’s Warehouse USA Local Technical Support

Tell us what you need. We’ll recommend suitable models, pricing and delivery options.

*
*

Shipping to:

USACanadaOthers
Submitting!
Submission successful!
Submission failed!
Invalid email address!
Incorrect phone number!

This will close in 0 seconds